Line 3: Line 3:
The '''testcontrol-server''' application has to be started from an account that has access to the '''cus''' engine (usually account cususer@PACS1 here at MPE). The communication between TOPE and CUS is done by the system wide '''X-server''' application. Hence, '''testcontrol-server''' has to be associated, via the DISPLAY variable, with the '''''irmultia''''' processor. The association is implemented as
{{{
(setenv DISPLAY irmultia:0 ; testcontrol-server &)
}}}
That is, redefine DISPLAY only for the '''testcontrol-server''' application and start the control application as a background task.
The '''testcontrol-server''' application is started automatically by the procedure that updates '''cus''' following adding or editing a script module into the CUS registry.
Line 10: Line 7:
[wiki:Self:PACS/FM_ILT_Procedures/DatabaseProcedures DatabaseProcedures] [[PACS/FM_ILT_Procedures/DatabaseProcedures|DatabaseProcedures]]
Line 14: Line 11:
attachment:dbsetup7.jpg {{attachment:dbsetup7.jpg}}
Line 16: Line 13:
* In the current configuration PACS5 is the operational database
   * "pacs_fm_ilt_2" is used as operational database
   * "pacs_fm_ilt_2" is used for commanding and telemetry ingestion
Line 17: Line 17:
[wiki:Self:PACS/FM_ILT/SetupCUS Setup to schedule CUS from TOPE]  * In the current configuration PACS1 is used for development of the CUS definitions and procedures.
   * "sftcode" is the CUS development database
   * "sftcode" is accessed from within MPE and remote via cusgui
Line 19: Line 21:
[wiki:Self:PACS/FM_ILT/CorrectCUS Correcting CUS procedures] [[PACS/FM_ILT/SetupCUS|Setup to schedule CUS from TOPE]]
Line 21: Line 23:
[wiki:Self:PACS/FM_ILT/SupportCUS Support Procedures] [[PACS/FM_ILT/CorrectCUS|Correcting CUS procedures]]
Line 23: Line 25:
[wiki:Self:PACS/FM_ILT/Use CUS for commanding] [[PACS/FM_ILT/SupportCUS|Support Procedures]]
Line 25: Line 27:
[wiki:Self:PACS/FM_ILT/CUSDev CUS Procedures Development] [[PACS/FM_ILT/CUSDev|CUS Procedures Development]]
Line 27: Line 29:
[wiki:Self:PACS/FM_ILT/CUSExp CUS Procedure export and configuration control] [[PACS/FM_ILT/CUSExp|CUS Procedure export and configuration control]]
Line 29: Line 31:
[wiki:Self:PACS/FM_ILT/CUSLoad CUS Procedures loading into operational Database] [[PACS/FM_ILT/CUSLoad|CUS Procedures loading into operational Database]]

To schedule a CUS "mode" script from TOPE requires the intervention of the testcontrol-server application.

The testcontrol-server application is started automatically by the procedure that updates cus following adding or editing a script module into the CUS registry.

The setup of the PACS MPE FM Databases are described : DatabaseProcedures

Current Datbase configuration for CUS use : dbsetup7.jpg

* In the current configuration PACS5 is the operational database

  • "pacs_fm_ilt_2" is used as operational database
  • "pacs_fm_ilt_2" is used for commanding and telemetry ingestion
  • In the current configuration PACS1 is used for development of the CUS definitions and procedures.
    • "sftcode" is the CUS development database
    • "sftcode" is accessed from within MPE and remote via cusgui

Setup to schedule CUS from TOPE

Correcting CUS procedures

Support Procedures

CUS Procedures Development

CUS Procedure export and configuration control

CUS Procedures loading into operational Database

Herschel: PACS/FM_ILT_Procedures/CUSprocedures (last edited 2009-07-15 14:32:36 by localhost)