Differences between revisions 15 and 16
Revision 15 as of 2021-07-28 15:43:49
Size: 2163
Editor: VadimBurwitz
Comment:
Revision 16 as of 2021-07-28 15:45:22
Size: 2672
Editor: VadimBurwitz
Comment:
Deletions are marked like this. Additions are marked like this.
Line 10: Line 10:
   18:45 CEST Firmware for the GM4000 HPS mount sucessfully updated to Version 3.04.
   23 15 CEST the System worked quite stable w/o Network issues over 4 hours.
JB 18:45 CEST Firmware for the GM4000 HPS mount sucessfully updated to Version 3.04.
JB 23 15 CEST the System worked quite stable w/o Network issues over 4 hours.
Line 18: Line 18:
PS 23:42 CEST Abot started after the change but the mount responds much slower than before,
              usually it responded with status update within less than one second, right now it is always over 3 seconds.
              It will slow down the whole image acquisition and will make LEO observations problematic
              (mount position update 3 seconds after the real position is a lot for low orbits).
              I will let you know if the system works ok once we will have a clear sky.

Provide a detailed log of all changes to hardware or software made to the observatory on this page.

2021 07 27 (Update mount Firmware)

VB 16:00 CEST Handed over Telescope control to Johannes Baader

JB 18:45 CEST Firmware for the GM4000 HPS mount sucessfully updated to Version 3.04. 
JB 23 15 CEST the System worked quite stable w/o Network issues over 4 hours. 
              After that we stopped monitoring. 
              Mount power was also checked: the Power on the mount was in a range of very rarely 23.8V to 25.0V 
              Even with the mount being still and parked all the time. 
              This is not considered flickery... 
              If the voltage drops bellow 24V the mount really does not like that.
              Most likely the power supply is not working perfectly anymore. 
PS 23:42 CEST Abot started after the change but the mount responds much slower than before, 
              usually it responded with status update within less than one second, right now it is always over 3 seconds. 
              It will slow down the whole image acquisition and will make LEO observations problematic 
              (mount position update 3 seconds after the real position is a lot for low orbits). 
              I will let you know if the system works ok once we will have a clear sky.

2021 02 23 (Install IMP Multiport Adapter)

VB 15:30 CET Stop abot 
             Roman Gümperlein (Baader) and Jesus Rodriguez (ESO/CAOS) were present for: 
               removing GOWI (CCD Camera) from IR90 focuser Rotator
               Attaching the IMP Multiport adapter to IR90 focuser Rotator
               Installing IMP software: running and connected on control PC 
               Attaching GOWI to IMP (direct beam)
               Attaching BACHES to IMP port ??       (BACHES need connecting)
               Attaching Eyepiece to IMP port ??   
VB 18:30 CET Restart ABOT
             New focus needs to be found

xx xx

2017 02 14

TS 20:35 CET Stop abot
TS 21:07 CET Restart abot (was still somehow running after stop abot.. make sure it's stopped properly before restarting)

2017 02 15

TS 17:00 CET Stop abot
             Dismount GOWI
             Mount BACHES

2017 08 01 reinstall GOWI

VB 09:00 CEST Removed FLI camera and reintalled GOWI = SBIG STX-16803 with GPS shutter timing modification 

2017 09 08 eduroam

VB 12:30 CEST Installed and tested eduroam access point in dome successfully 