Line 5: Line 5:
= A new MIB (combination) is available and ready to be used = = Standard Procedures =
Line 7: Line 7:
A single procedure named "loadMIB" is used to ingest the MIB
into both the operations and the CUS development databases.
== A new MIB (combination) is available and ready to be used ==
Line 13: Line 12:
loadMIB --loadmib PACS_MIB_TAG EGSE_MIB_TAG CDMSSIM_MIB_TAG ccm -loadmib PACS_MIB_TAG EGSE_MIB_TAG CDMSSIM_MIB_TAG
Line 17: Line 16:
loadMib --loadmib=MIB_LABEL ccm -loadmib=MIB_LABEL
Line 23: Line 22:
= A new (modifiable) instrumentModel shall be created using new MIB definition =
== A new (modifiable) instrumentModel shall be created using new MIB definition ==

The MIB must be already ingested into the database using the above procedure.

Depending from the source for the initial CUS definitions two command options
are available.

 * Using an existing version from the CUS CVS repository specified by a CVS tag name which is formed like a MissionConfigurationLabel.
 {{{
 ccm -createmodel -usemib=MIB_LABEL -usecus=cvs=CvsTagName CVScomment
 }}}

 * Using the current CUS definitions from an existing (modifiable) instrumentModel in the database specified by an InstrumentModelLabel name.
 {{{
 ccm -createmodel -usemib=MIB_LABEL -usecus=im=InstrumentModelLabel CVScomment
 }}}

Each of these options will create an instrumentModel, load it with the specified MIB, load the requested CUS
definitions (also updating the CVS repository) and create the first missionConfiguration for this new instrumentModel. Finally the property file
will be updated with the new instrumentModel and missionConfiguration and the test-control server will be
restarted.

<!> '''Note:''' The CUS editor "cusgui" must be restarted to view (and edit) the new modifiable instrumentModel.

== Publish CUS modifications for the current instrumentModel ==

Whenever you want to make the CUS modification edited with the CUS editor available for commanding you must
commit your changes to the database to update the instrumentModel and you must use the following command to
create a new missionConfiguration and make it available.
Line 26: Line 54:
createInstrumentModel --create MIB_LABEL ccm -cusupdate CVScomment
Line 29: Line 57:
This command will create a new modifiable instrumentModel in the operations
database. The corresponding MIB will automatically associated with this new
instrumentModel.

The [:InstrumentModelLabel: instrumentModel label] in the database will be formed according the given
[:MibLabels: MibLabel]. If there is already an instrumentModel with this label the command
will fail. To create a new version use the ''--force'' option.
{{{
createInstrumentModel --create MIB_LABEL --force
}}}

To load the initial CUS definitions (procedures and table) two options exist. Either copy
the CUS definitions from an existing instrumentModel or use a tagged version from the CVS repository.

{{{
createInstrumentModel --loadcus=cvs=tagname instrumentModelLabel
}}}
or
{{{
createInstrumentModel --loadcus=instmodel=label instrumentModelLabel
}}}

Describe PACS/FM ILT Procedures/CCMprocedures here.

TableOfContents(2)

Standard Procedures

A new MIB (combination) is available and ready to be used

The MIB to be ingested can be specified in two different ways, either by the CVS MibTags or by the database MibLabels.

ccm -loadmib PACS_MIB_TAG EGSE_MIB_TAG CDMSSIM_MIB_TAG

or

ccm -loadmib=MIB_LABEL

The MIB loading does not affect any ongoing operation. It can be executed at any time.

A new (modifiable) instrumentModel shall be created using new MIB definition

The MIB must be already ingested into the database using the above procedure.

Depending from the source for the initial CUS definitions two command options are available.

  • Using an existing version from the CUS CVS repository specified by a CVS tag name which is formed like a MissionConfigurationLabel.

     ccm -createmodel -usemib=MIB_LABEL -usecus=cvs=CvsTagName CVScomment
  • Using the current CUS definitions from an existing (modifiable) instrumentModel in the database specified by an InstrumentModelLabel name.

     ccm -createmodel -usemib=MIB_LABEL -usecus=im=InstrumentModelLabel CVScomment

Each of these options will create an instrumentModel, load it with the specified MIB, load the requested CUS definitions (also updating the CVS repository) and create the first missionConfiguration for this new instrumentModel. Finally the property file will be updated with the new instrumentModel and missionConfiguration and the test-control server will be restarted.

<!> Note: The CUS editor "cusgui" must be restarted to view (and edit) the new modifiable instrumentModel.

Publish CUS modifications for the current instrumentModel

Whenever you want to make the CUS modification edited with the CUS editor available for commanding you must commit your changes to the database to update the instrumentModel and you must use the following command to create a new missionConfiguration and make it available.

ccm -cusupdate CVScomment