Size: 5268
Comment:
|
← Revision 41 as of 2009-07-15 14:32:38 ⇥
Size: 5169
Comment: converted to 1.6 markup
|
Deletions are marked like this. | Additions are marked like this. |
Line 1: | Line 1: |
=Spectroscopy Setup= | = Spectroscopy Setup = |
Line 4: | Line 4: |
== Dynamic range per capacitance == | == Dynamic range per capacitance (1.2.3) == |
Line 8: | Line 8: |
* Note, that the related PTD contains a combined measurement of 1.2.3, 1.2.8 and 1.2.18 blocks, and cannot be applied in its original form. | |
Line 11: | Line 12: |
* Below are all combinations of the OGBE BB temperature, integration capacitor and reset interval values. Note, that the parameter of the SPEC_dynamic_range_fmilt123_OBS CUS script is the ramp length, and not the reset interval! (1/16s -> 16; 1/4s -> 64; 1/2s -> 128; 2s -> 512). The integration capacitor/reset interval block is performed for two grating positions: GR-1 = 760000 and GR-2 = 490000. | * Each measurement block (OGSE BB temperature setup) runs through all combinations of integration capacitor (0.1pF, 0.3pF, 1pF, 3pF) and reset interval values (1/8s, 1/4s, 1/2s, 2s), and is performed for two grating positions (GR-1 = 760000 and GR-2 = 490000). |
Line 15: | Line 16: |
|| GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || |
|
Line 28: | Line 17: |
|| GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || |
|
Line 44: | Line 20: |
|| GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || |
|
Line 58: | Line 21: |
|| GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || |
|
Line 74: | Line 24: |
|| GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || |
|
Line 88: | Line 25: |
|| GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || |
|
Line 105: | Line 28: |
|| GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || |
|
Line 120: | Line 29: |
|| GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || || 1/16s || || || || || || 1/4s || || || || || || 1/2s || || || || || || 2s || || || || || |
|
Line 135: | Line 31: |
* Measurements / Preliminary analysis : FmIltAnal/DynamicRangeSpectro | == Signal dependence on chopper frequency (1.2.8) == * Procedures : FmIltProc/DynamicRangeSpectro * Pre-test setup: * CS1 temperature: 70.5K (fixed) * CS2 temperature: 76.0K (fixed) * Grating: 425250 (fixed) * Reset interval: 1/4s (fixed) * SPU setup: Entire slope fitting * Set the OGSE BB1 temperature (SET_UP_OGSE_BB_TEMP_OBS, see the temperatures below) * Move filter wheel to "POS B" (SPEC_fltw_move) * CUS script: SPEC_chopper_freq_fmilt128_obs * Each measurement block (OGSE BB temperature setup) performs a tringular chopping measurement between the calibration sources and the OGSE BB1 as OGSE BB1 --> CS1 --> OGSE BB1 --> CS2 --> OBSE BB1 --> CS1 --> ... * Setup #1: OBSE BB1: 18.8K * Setup #2: OBSE BB1: 25.4K * Setup #3: OBSE BB1: 32.5K * Setup #4: OBSE BB1: 40.7K * Setup #5: OBSE BB1: 48.0K * Setup #6: OBSE BB1: 61.4K ? * Setup #7: OBSE BB1: 77.0K ? * Estimated duration of the tests for each indivitual OGSE BB setting: ~0.45h == Time constants: flux changes, spectrometer (1.2.18) == * Procedures : FmIltProc/DynamicRangeSpectro * Pre-test setup: * Grating: 425250 (fixed) * Reset interval: 1/4s (fixed) * Integration capacitor: should be adjusted according to 1.2.3 * SPU setup: Entire slope fitting * Set the OGSE BB1 temperature (SET_UP_OGSE_BB_TEMP_OBS, see the temperatures below) * Move filter wheel to "POS B" (SPEC_fltw_move) * Move chopper to CFOV * CUS script: SPEC_time_constant_fmilt1218_obs * Each measurement block (OGSE BB temperature setup) performs the following measurement: the detector is staring at the OGSE BB1 source, and the filter wheel is rotated back and forth. * Setup #1: OBSE BB1: 18.8K * Setup #2: OBSE BB1: 25.4K * Setup #3: OBSE BB1: 32.5K * Setup #4: OBSE BB1: 40.7K * Setup #5: OBSE BB1: 48.0K * Setup #6: OBSE BB1: 61.4K ? * Setup #7: OBSE BB1: 77.0K ? * Estimated duration of the tests for each indivitual OGSE BB setting: ~0.25h, without OGSE BB stabilization. == Measurements in Buffer Transmission Mode == || Date || Tm File |||| Conditions || CUS || Comments || || || || BB || Temp || || || || 20070321 || FILT_Batch_20070321_SPEC_dyn_range_raw_OBS_97.tm || BB 1 || 4K (Dark)|| SPEC_dyn_range_raw_OBS || || || 20070326 || FILT_Batch_20070326_SPEC_dyn_range_raw_OBS_296.tm || BB 2 || 22.2 K || SPEC_dyn_range_raw_OBS || || || 20070327 || FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_322.tm || BB 1 || 21.8 K || SPEC_dyn_range_raw_OBS || || || 20070327 || FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_325.tm || BB 2 || 22.6 K || SPEC_dyn_range_raw_OBS || || || 20070327 || FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_329.tm || BB 2 || 23.7 K || SPEC_dyn_range_raw_OBS || || || 20070327 || FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_333.tm || BB 2 || 25.2 K || SPEC_dyn_range_raw_OBS || || || 20070327 || FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_338.tm || BB 2 || 35.4 K || SPEC_dyn_range_raw_OBS || || || 20070327 || FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_341.tm || BB 1 || 34.9 K || SPEC_dyn_range_raw_OBS || || || 20070328 || FILT_Batch_20070328_SPEC_dyn_range_raw_OBS_421.tm || BB 2 || 39.1 K || SPEC_dyn_range_raw_OBS || || || 20070404 || FILT_Batch_20070404_SPEC_dyn_range_raw_OBS_22.tm || BB 1 || 35.9 K || SPEC_dyn_range_raw_OBS || || || 20070404 || FILT_Batch_20070404_SPEC_dyn_range_raw_OBS_25.tm || BB 1 || 37.3 K || SPEC_dyn_range_raw_OBS || || || 20070404 || FILT_Batch_20070404_SPEC_dyn_range_raw_OBS_27.tm || BB 1 || 39.1 K || SPEC_dyn_range_raw_OBS || || |
Spectroscopy Setup
Dynamic range per capacitance (1.2.3)
Procedures : FmIltProc/DynamicRangeSpectro
- Pre-test setup:
- Note, that the related PTD contains a combined measurement of 1.2.3, 1.2.8 and 1.2.18 blocks, and cannot be applied in its original form.
- Set the OGSE BB temperatures (SET_UP_OGSE_BB_TEMP_OBS, see the temperatures below)
- Move filter wheel to "POS A" (SPEC_fltw_move)
CUS scripts: SPEC_dyn_range_obs, SPEC_DiagHK_DynRange_block_stop, SPEC_DiagHK_DynRange_block_start
- Each measurement block (OGSE BB temperature setup) runs through all combinations of integration capacitor (0.1pF, 0.3pF, 1pF, 3pF) and reset interval values (1/8s, 1/4s, 1/2s, 2s), and is performed for two grating positions (GR-1 = 760000 and GR-2 = 490000).
- Setup #1: OBSE BB1: 16.3K, OGSE BB2: 15.7K
- Setup #2: OBSE BB1: 18.8K, OGSE BB2: 18.2K
- Setup #3: OBSE BB1: 25.4K, OGSE BB2: 24.6K
- Setup #4: OBSE BB1: 32.5K, OGSE BB2: 31.5K
- Setup #5: OBSE BB1: 40.7K, OGSE BB2: 39.3K
- Setup #6: OBSE BB1: 48.0K, OGSE BB2: 46.0K
- Setup #7: OBSE BB1: 61.4K, OGSE BB2: 58.6K
- Setup #8: OBSE BB1: 77.0K, OGSE BB2: 73.0K
- Estimated duration of the tests for each indivitual OGSE BB setting: 2x4x4x128s + 2x15s for grating movement + 1080s OGSE BB stabilization = 1.45h
Signal dependence on chopper frequency (1.2.8)
Procedures : FmIltProc/DynamicRangeSpectro
- Pre-test setup:
- CS1 temperature: 70.5K (fixed)
- CS2 temperature: 76.0K (fixed)
- Grating: 425250 (fixed)
- Reset interval: 1/4s (fixed)
- SPU setup: Entire slope fitting
- Set the OGSE BB1 temperature (SET_UP_OGSE_BB_TEMP_OBS, see the temperatures below)
- Move filter wheel to "POS B" (SPEC_fltw_move)
- CUS script: SPEC_chopper_freq_fmilt128_obs
Each measurement block (OGSE BB temperature setup) performs a tringular chopping measurement between the calibration sources and the OGSE BB1 as OGSE BB1 --> CS1 --> OGSE BB1 --> CS2 --> OBSE BB1 --> CS1 --> ...
- Setup #1: OBSE BB1: 18.8K
- Setup #2: OBSE BB1: 25.4K
- Setup #3: OBSE BB1: 32.5K
- Setup #4: OBSE BB1: 40.7K
- Setup #5: OBSE BB1: 48.0K
- Setup #6: OBSE BB1: 61.4K ?
- Setup #7: OBSE BB1: 77.0K ?
- Estimated duration of the tests for each indivitual OGSE BB setting: ~0.45h
Time constants: flux changes, spectrometer (1.2.18)
Procedures : FmIltProc/DynamicRangeSpectro
- Pre-test setup:
- Grating: 425250 (fixed)
- Reset interval: 1/4s (fixed)
- Integration capacitor: should be adjusted according to 1.2.3
- SPU setup: Entire slope fitting
- Set the OGSE BB1 temperature (SET_UP_OGSE_BB_TEMP_OBS, see the temperatures below)
- Move filter wheel to "POS B" (SPEC_fltw_move)
- Move chopper to CFOV
- CUS script: SPEC_time_constant_fmilt1218_obs
- Each measurement block (OGSE BB temperature setup) performs the following measurement: the detector is staring at the OGSE BB1 source, and the filter wheel is rotated back and forth.
- Setup #1: OBSE BB1: 18.8K
- Setup #2: OBSE BB1: 25.4K
- Setup #3: OBSE BB1: 32.5K
- Setup #4: OBSE BB1: 40.7K
- Setup #5: OBSE BB1: 48.0K
- Setup #6: OBSE BB1: 61.4K ?
- Setup #7: OBSE BB1: 77.0K ?
- Estimated duration of the tests for each indivitual OGSE BB setting: ~0.25h, without OGSE BB stabilization.
Measurements in Buffer Transmission Mode
Date |
Tm File |
Conditions |
CUS |
Comments |
|
|
|
BB |
Temp |
|
|
20070321 |
FILT_Batch_20070321_SPEC_dyn_range_raw_OBS_97.tm |
BB 1 |
4K (Dark) |
SPEC_dyn_range_raw_OBS |
|
20070326 |
FILT_Batch_20070326_SPEC_dyn_range_raw_OBS_296.tm |
BB 2 |
22.2 K |
SPEC_dyn_range_raw_OBS |
|
20070327 |
FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_322.tm |
BB 1 |
21.8 K |
SPEC_dyn_range_raw_OBS |
|
20070327 |
FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_325.tm |
BB 2 |
22.6 K |
SPEC_dyn_range_raw_OBS |
|
20070327 |
FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_329.tm |
BB 2 |
23.7 K |
SPEC_dyn_range_raw_OBS |
|
20070327 |
FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_333.tm |
BB 2 |
25.2 K |
SPEC_dyn_range_raw_OBS |
|
20070327 |
FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_338.tm |
BB 2 |
35.4 K |
SPEC_dyn_range_raw_OBS |
|
20070327 |
FILT_Batch_20070327_SPEC_dyn_range_raw_OBS_341.tm |
BB 1 |
34.9 K |
SPEC_dyn_range_raw_OBS |
|
20070328 |
FILT_Batch_20070328_SPEC_dyn_range_raw_OBS_421.tm |
BB 2 |
39.1 K |
SPEC_dyn_range_raw_OBS |
|
20070404 |
FILT_Batch_20070404_SPEC_dyn_range_raw_OBS_22.tm |
BB 1 |
35.9 K |
SPEC_dyn_range_raw_OBS |
|
20070404 |
FILT_Batch_20070404_SPEC_dyn_range_raw_OBS_25.tm |
BB 1 |
37.3 K |
SPEC_dyn_range_raw_OBS |
|
20070404 |
FILT_Batch_20070404_SPEC_dyn_range_raw_OBS_27.tm |
BB 1 |
39.1 K |
SPEC_dyn_range_raw_OBS |
|