5172
Comment:
|
5276
|
Deletions are marked like this. | Additions are marked like this. |
Line 7: | Line 7: |
* CUS scripts: SPEC_dynamic_range_fmilt123_OBS, SPEC_DiagHK_DynRange_block_stop, SPEC_DiagHK_DynRange_block_start * Below are all combinations of the OGBE BB temperature, integration capacitor and reset interval values. Note, that the parameter of the SPEC_dynamic_range_fmilt123_OBS CUS script is the ramp length, and not the reset interval! (1/16s -> 16; 1/4s -> 64; 1/2s -> 128; 2s -> 512). The integration capacitor/reset interval block is performed for both the 2nd and 3rd grating orders. |
* Pre-test setup: * Set the OGSE BB temperatures (SET_UP_OGSE_BB_TEMP_OBS, see the temperatures below) * Move filter wheel to grating order 2 (SPEC_fltw_move) * CUS scripts: SPEC_dyn_range_obs, SPEC_DiagHK_DynRange_block_stop, SPEC_DiagHK_DynRange_block_start * Below are all combinations of the OGBE BB temperature, integration capacitor and reset interval values. Note, that the parameter of the SPEC_dynamic_range_fmilt123_OBS CUS script is the ramp length, and not the reset interval! (1/16s -> 16; 1/4s -> 64; 1/2s -> 128; 2s -> 512). The integration capacitor/reset interval block is performed for two grating positions: GR-1 = 760000 and GR-2 = 490000. |
Line 12: | Line 15: |
|| 2nd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 18: | Line 21: |
|| 3rd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 26: | Line 29: |
|| 2nd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 32: | Line 35: |
|| 3rd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 39: | Line 42: |
* Setup #1: OBSE BB1: 25.4K, OGSE BB2: 24.6K | * Setup #3: OBSE BB1: 25.4K, OGSE BB2: 24.6K |
Line 42: | Line 45: |
|| 2nd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 48: | Line 51: |
|| 3rd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 54: | Line 57: |
* Setup #1: OBSE BB1: 32.5K, OGSE BB2: 31.5K | * Setup #4: OBSE BB1: 32.5K, OGSE BB2: 31.5K |
Line 57: | Line 60: |
|| 2nd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 63: | Line 66: |
|| 3rd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 69: | Line 72: |
* Setup #1: OBSE BB1: 40.7K, OGSE BB2: 39.3K | * Setup #5: OBSE BB1: 40.7K, OGSE BB2: 39.3K |
Line 72: | Line 75: |
|| 2nd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 78: | Line 81: |
|| 3rd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 84: | Line 87: |
* Setup #1: OBSE BB1: 48.0K, OGSE BB2: 46.0K | * Setup #6: OBSE BB1: 48.0K, OGSE BB2: 46.0K |
Line 87: | Line 90: |
|| 2nd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 93: | Line 96: |
|| 3rd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 100: | Line 103: |
* Setup #1: OBSE BB1: 61.4K, OGSE BB2: 58.6K | * Setup #7: OBSE BB1: 61.4K, OGSE BB2: 58.6K |
Line 103: | Line 106: |
|| 2nd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 109: | Line 112: |
|| 3rd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 116: | Line 119: |
* Setup #1: OBSE BB1: 77.0K, OGSE BB2: 73.0K | * Setup #8: OBSE BB1: 77.0K, OGSE BB2: 73.0K |
Line 119: | Line 122: |
|| 2nd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-1 || 0.1pF || 0.3pF || 1pF || 3pF || |
Line 125: | Line 128: |
|| 3rd order || 0.1pF || 0.3pF || 1pF || 3pF || | || GR-2 || 0.1pF || 0.3pF || 1pF || 3pF || |
=Spectroscopy Setup=
Dynamic range per capacitance
Procedures : FmIltProc/DynamicRangeSpectro
- Pre-test setup:
- Set the OGSE BB temperatures (SET_UP_OGSE_BB_TEMP_OBS, see the temperatures below)
- Move filter wheel to grating order 2 (SPEC_fltw_move)
CUS scripts: SPEC_dyn_range_obs, SPEC_DiagHK_DynRange_block_stop, SPEC_DiagHK_DynRange_block_start
Below are all combinations of the OGBE BB temperature, integration capacitor and reset interval values. Note, that the parameter of the SPEC_dynamic_range_fmilt123_OBS CUS script is the ramp length, and not the reset interval! (1/16s -> 16; 1/4s -> 64; 1/2s -> 128; 2s -> 512). The integration capacitor/reset interval block is performed for two grating positions: GR-1 = 760000 and GR-2 = 490000.
- Setup #1: OBSE BB1: 16.3K, OGSE BB2: 15.7K
GR-1
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
GR-2
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
- Setup #2: OBSE BB1: 18.8K, OGSE BB2: 18.2K
GR-1
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
GR-2
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
- Setup #3: OBSE BB1: 25.4K, OGSE BB2: 24.6K
GR-1
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
GR-2
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
- Setup #4: OBSE BB1: 32.5K, OGSE BB2: 31.5K
GR-1
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
GR-2
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
- Setup #5: OBSE BB1: 40.7K, OGSE BB2: 39.3K
GR-1
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
GR-2
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
- Setup #6: OBSE BB1: 48.0K, OGSE BB2: 46.0K
GR-1
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
GR-2
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
- Setup #7: OBSE BB1: 61.4K, OGSE BB2: 58.6K
GR-1
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
GR-2
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
- Setup #8: OBSE BB1: 77.0K, OGSE BB2: 73.0K
GR-1
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
GR-2
0.1pF
0.3pF
1pF
3pF
1/16s
1/4s
1/2s
2s
- Setup #1: OBSE BB1: 16.3K, OGSE BB2: 15.7K
- Estimated duration of the tests for each indivitual OGSE BB setting: 2x4x4x128s + 2x15s for grating movement + 1080s OGSE BB stabilization = 1.45h