Size: 1962
Comment:
|
Size: 1990
Comment:
|
Deletions are marked like this. | Additions are marked like this. |
Line 9: | Line 9: |
A loop over steps C & D can be implemented for a number of thresholds | A loop over steps 3 & 4 can be implemented for a number of thresholds |
Line 11: | Line 11: |
|| || Script || TCL || Parameters || Comments || ||A|| PACS_Phot_HK_Setup_OBS || || || || ||B|| PACS_Phot_Fil_Diaghk_Setup_OBS || || || || ||C|| CONF_phot_fltw_param_OBS || Yes || threshold || || ||D|| PACS_Phot_Fil_nturns_OBS || Yes || nturns : number of full turns of the FW || || ||E|| PACS_Diaghk_Reset_OBS || || || || ||F|| PACS_SAFE_MODE.tcl || || || || |
|| || Script || TCL || Parameters || Comments || || 1 || PACS_Phot_HK_Setup_OBS || || || || || 2 || PACS_Phot_Fil_Diaghk_Setup_OBS || || || || || 3 || CONF_phot_fltw_param_OBS || Yes || threshold || || || 4 || PACS_Phot_Fil_nturns_OBS || Yes || nturns : number of full turns of the FW || || || 5 || PACS_Diaghk_Reset_OBS || || || || || 6 || PACS_SAFE_MODE.tcl || || || || |
Line 22: | Line 22: |
A loop over steps C & D can be implemented for a number of thresholds | A loop over steps 3 & 4 can be implemented for a number of thresholds |
Line 24: | Line 24: |
|| || Script || TCL || Parameters || Comments || ||A|| PACS_Spec_HK_Setup_OBS || || || || ||B|| PACS_Spec_Fil_Diaghk_Setup_OBS || || || || ||C|| CONF_spec_fltw_param_OBS || Yes || threshold || || ||D|| PACS_Spec_Fil_nturns_OBS || Yes || nturns : number of full turns of the FW || || ||E|| PACS_Diaghk_Reset_OBS || || || || ||F|| PACS_SAFE_MODE.tcl || || || || |
|| || Script || TCL || Parameters || Comments || || 1 || PACS_Spec_HK_Setup_OBS || || || || || 2 || PACS_Spec_Fil_Diaghk_Setup_OBS || || || || || 3 || CONF_spec_fltw_param_OBS || Yes || threshold || || || 4 || PACS_Spec_Fil_nturns_OBS || Yes || nturns : number of full turns of the FW || || || 5 || PACS_Diaghk_Reset_OBS || || || || || 6 || PACS_SAFE_MODE.tcl || || || || |
1. Filter Wheel control loop procedures
2. Conditions
All tests described can be executed from SAFE MODE of from SPECTROSCOPY.
3. 1. Treshold parameter optimisation Photometer filter wheel
A loop over steps 3 & 4 can be implemented for a number of thresholds
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Phot_HK_Setup_OBS |
|
|
|
2 |
PACS_Phot_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
CONF_phot_fltw_param_OBS |
Yes |
threshold |
|
4 |
PACS_Phot_Fil_nturns_OBS |
Yes |
nturns : number of full turns of the FW |
|
5 |
PACS_Diaghk_Reset_OBS |
|
|
|
6 |
PACS_SAFE_MODE.tcl |
|
|
|
4. 2. Treshold parameter optimisation Spectrometer filter wheel
A loop over steps 3 & 4 can be implemented for a number of thresholds
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Spec_HK_Setup_OBS |
|
|
|
2 |
PACS_Spec_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
CONF_spec_fltw_param_OBS |
Yes |
threshold |
|
4 |
PACS_Spec_Fil_nturns_OBS |
Yes |
nturns : number of full turns of the FW |
|
5 |
PACS_Diaghk_Reset_OBS |
|
|
|
6 |
PACS_SAFE_MODE.tcl |
|
|
|