1. Filter Wheel control loop procedures
2. Conditions
All tests described can be executed from SAFE MODE of from SPECTROSCOPY.
3. Control parameters I : identical parameters for both positions
3.1. Threshold
3.1.1. Photometer filter wheel
A loop over steps 3 & 4 can be implemented for a number of thresholds
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Phot_HK_Setup_OBS |
|
|
|
2 |
PACS_Phot_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
CONF_phot_fltw_param_OBS |
Yes |
rate,drive_current,threshold |
|
4 |
PACS_Phot_Fil_nturns_OBS |
Yes |
nturns : number of full turns of the FW |
|
5 |
PACS_Diaghk_Reset_OBS |
|
|
|
6 |
PACS_SAFE_MODE.tcl |
|
|
|
3.1.2. Spectrometer filter wheel
A loop over steps 3 & 4 can be implemented for a number of thresholds
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Spec_HK_Setup_OBS |
|
|
|
2 |
PACS_Spec_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
CONF_spec_fltw_param_OBS |
Yes |
rate,drive_current,threshold |
|
4 |
PACS_Spec_Fil_nturns_OBS |
Yes |
nturns : number of full turns of the FW |
|
5 |
PACS_Diaghk_Reset_OBS |
|
|
|
6 |
PACS_SAFE_MODE.tcl |
|
|
|
3.2. Current loop
Loop over current from 10 to 100mA by steps of 10. For each setting, performs nturns *OPEN LOOP* movements of 360 degrees (default = 3). Open loop movement means that the wheel is driven for a given time, depending on the size of the movement and the rate. Consequently, the movement might finally not be of the expected size.
3.2.1. Photometer filter wheel
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Phot_HK_Setup_OBS |
|
|
|
2 |
PACS_Phot_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
CONF_phot_fltw_param_OBS |
Yes |
rate,drive_current,threshold |
|
4 |
PACS_Phot_Fil_Current_Loop_OBS |
No |
nturns : #turns of the FW/current setting |
|
5 |
PACS_Diaghk_Reset_OBS |
|
|
|
6 |
PACS_SAFE_MODE.tcl |
|
|
|
3.3. Rate
The following test aims at checking the feasability and behaviour stability of the FWs operated at higher rates (= higher speed). The baseline rate = 100, corresponding to an angular speed of 360 degrees in 18.75 seconds.
3.3.1. Photometer filter wheel
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Phot_HK_Setup_OBS |
|
|
|
2 |
PACS_Phot_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
CONF_phot_fltw_param_OBS |
Yes |
rate,drive_current,threshold |
|
4 |
PACS_Phot_Fil_nturns_OBS |
Yes |
nturns : #turns of the FW |
|
5 |
PACS_Diaghk_Reset_OBS |
|
|
|
6 |
PACS_SAFE_MODE.tcl |
|
|
|
4. Control parameters II : parameters tuned for each filter position
Here the control parameters are commanded before each FW movement. The goal is to use very high threshold values, tuned for each position individually.
4.1. Photometer filter wheel
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Phot_HK_Setup_OBS |
|
|
|
2 |
PACS_Phot_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
PACS_Phot_Fil_nturns_config_OBS |
Yes |
nturns (of the FW), rate (threshold A & B hardcoded) |
|
4 |
PACS_Diaghk_Reset_OBS |
|
|
|
5 |
PACS_SAFE_MODE.tcl |
|
|
|
4.2. Spectrometer filter wheel
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Spec_HK_Setup_OBS |
|
|
|
2 |
PACS_Spec_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
PACS_Spec_Fil_nturns_config_OBS |
Yes |
nturns (of the FW), rate (threshold A & B hardcoded) |
|
4 |
PACS_Diaghk_Reset_OBS |
|
|
|
5 |
PACS_SAFE_MODE.tcl |
|
|
|
5. Influence of disconnecting redundant connector
The following procedure may be applied w/ or w/o short circuit connector.
|
Script |
TCL |
Parameters |
Comments |
1 |
Disconnect redundant, place short-circuit connector |
|
|
|
2 |
PACS_switch_on.tcl |
Yes |
|
|
3 |
PACS_Phot_HK_Setup_OBS |
|
|
|
4 |
PACS_Phot_Fil_Diaghk_Setup_OBS |
|
|
|
5 |
CONF_phot_fltw_param_OBS |
Yes |
rate 100,drive_current 4096,threshold 2000 |
|
6 |
PACS_Phot_Fil_nturns_OBS |
Yes |
nturns=6 |
437 sec |
7 |
PACS_Phot_Fil_nturns_twodirections_OBS |
Yes |
num_repeats=2, num_turns=3, slew_time=15 |
981 sec |
8 |
PACS_Phot_Fil_nturns_finepos_OBS |
Yes |
nturns=2 |
1484 sec |
9 |
CONF_phot_fltw_param_OBS |
Yes |
rate=200,drive_current 4096,threshold 2000 |
|
10 |
PACS_Phot_Fil_nturns_twodirections_OBS |
Yes |
num_repeats=2, num_turns=3, slew_time=30 |
1716 sec |
11 |
PACS_Diaghk_Reset_OBS |
|
|
|
12 |
PACS_Spec_HK_Setup_OBS |
|
|
|
13 |
PACS_Spec_Fil_Diaghk_Setup_OBS |
|
|
|
14 |
CONF_spec_fltw_param_OBS |
Yes |
rate 100,drive_current 4096,threshold 2000 |
|
15 |
PACS_Spec_Fil_nturns_OBS |
Yes |
nturns=6 |
437 sec |
16 |
PACS_Spec_Fil_nturns_twodirections_OBS |
Yes |
num_repeats=2, num_turns=3, slew_time=15 |
918 sec |
17 |
PACS_Spec_Fil_nturns_finepos_OBS |
Yes |
nturns=2 |
1484 sec |
18 |
CONF_Spec_fltw_param_OBS |
Yes |
rate=200,drive_current 4096,threshold 2000 |
|
19 |
PACS_Spec_Fil_nturns_twodirections_OBS |
Yes |
num_repeats=2, num_turns=3, slew_time=30 |
1716 sec |
20 |
PACS_Diaghk_Reset_OBS |
|
|
|
21 |
PACS_switch_off.tcl |
|
|
|
6. Check the amplitude of the Trapping Pit around the stop positions
1. Move by 1, 2, ... maxkick degrees from each stop position
2. Repeat those "open loop" movements from + and from - 45 degrees from each stop position
6.1. Photometer filter wheel
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Phot_HK_Setup_OBS |
|
|
|
2 |
PACS_Phot_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
CONF_phot_fltw_param_OBS |
Yes |
rate,drive_current,threshold 50,4096,2000 |
|
4 |
PACS_Phot_Fil_nturns_OBS |
Yes |
nturns (3) |
|
5 |
PACS_Phot_Fil_Trapping_DEG_MODE_OBS |
No |
num_iter,maxkick |
|
6 |
PACS_Diaghk_Reset_OBS |
|
|
|
7 |
PACS_SAFE_MODE.tcl |
|
|
|
6.2. Spectrometer filter wheel
|
Script |
TCL |
Parameters |
Comments |
1 |
PACS_Spec_HK_Setup_OBS |
|
|
|
2 |
PACS_Spec_Fil_Diaghk_Setup_OBS |
|
|
|
3 |
CONF_spec_fltw_param_OBS |
Yes |
rate,drive_current,threshold 50,4096,2000 |
|
4 |
PACS_Spec_Fil_nturns_OBS |
Yes |
nturns (3) |
|
5 |
PACS_Spec_Fil_Trapping_DEG_MODE_OBS |
No |
num_iter,maxkick |
|
6 |
PACS_Diaghk_Reset_OBS |
|
|
|
7 |
PACS_SAFE_MODE.tcl |
|
|
|