Differences between revisions 9 and 11 (spanning 2 versions)
Revision 9 as of 2014-04-04 10:02:29
Size: 1184
Editor: VadimBurwitz
Comment:
Revision 11 as of 2014-04-04 10:08:37
Size: 1328
Editor: VadimBurwitz
Comment:
Deletions are marked like this. Additions are marked like this.
Line 9: Line 9:
and connected to mount and focuser respectively.

This should usally be the case.
 and connected to mount and focuser respectively.
 
 This should usally be the case.
Line 16: Line 16:
 * Log on to '''ePower #1'''

* Check if focuser and mount are powered on '''ePower #1'''.
 * Then Log on to '''ePower #1''' and check if focuser and mount are powered on '''ePower #1'''.
Line 21: Line 19:
 * Power up the focuser is necessary  * Power up the '''focuser''' if necessary and check the the '''focuser''' control is running and connected.
Line 23: Line 21:
 * Power up mount if necessery: (switch on power supply, then toggle mount switch both on ePowerSwitch #1)  * Power up '''mount''' if necessery:
  *
switch on power supply on '''ePower #1'''
 {{attachment:ePower01AllOnCCDoffMarked.JPG}}
  *
then toggle mount switch both on '''ePower #1''')
Line 25: Line 26:
 * power imager(s) if not already powered up (ethernet PDU)

 * Power up imager/s on '''ePower #1'''

How to start up observatory

  • Check weather (outside conditions)

  • Log on to control PC via VNC skydome.mpe.mpg.de port 5200

  • 1st check if mount handpad program and focuser program are running and connected to mount and focuser respectively. This should usally be the case.

  • If they are not started, start up windows internet explorer.
    • PC2_expl_weather_ePower01Marked.JPG

  • Then Log on to ePower #1 and check if focuser and mount are powered on ePower #1.

    • ePower01AllOnCCDoffMarked.JPG

  • Power up the focuser if necessary and check the the focuser control is running and connected.

  • Power up mount if necessery:

    • switch on power supply on ePower #1

    ePower01AllOnCCDoffMarked.JPG

    • then toggle mount switch both on ePower #1)

      • if not yet powered up (usually it should be powered up).
  • Power up imager/s on ePower #1

  • open dome

How to start up GOWI

  • cool imager to target temperature (-30C typically)
  • start dark and bias frame sequence
  • set focuser to expected setting for the night (if known)
  • take skyflats until start of actual observations