Differences between revisions 30 and 34 (spanning 4 versions)
Revision 30 as of 2014-04-04 12:39:32
Size: 3109
Editor: VadimBurwitz
Comment:
Revision 34 as of 2014-04-04 14:53:53
Size: 3121
Editor: VadimBurwitz
Comment:
Deletions are marked like this. Additions are marked like this.
Line 18: Line 18:
 * Power up the '''focuser''' if necessary and check the the '''focuser''' control program is running and connected.  * Power up the '''focuser''' if necessary and check that the '''focuser''' control program is running and connected.
Line 33: Line 33:
--- ----
Line 58: Line 58:
 * Power up the '''focuser''' if necessary and check the the '''focuser''' control program is running and connected.  * Power up the '''focuser''' if necessary and check that the '''focuser''' control program is running and connected.
Line 75: Line 75:
--- ----
Line 83: Line 83:

----

How to start up observatory (no embedded images)

  • Check weather (outside conditions) use common sense

  • Log on to control PC via VNC skydome.mpe.mpg.de port 5200

  • 1st check if mount handpad program and focuser program are running and connected to mount and focuser respectively.

    • This should usally be the case.
    • If not start the programs and try to connect.
  • If they are not started, and cannot connect, then start up windows internet explorer.
  • Then Log on to ePower #1 and check if focuser and mount are powered on ePower #1.

  • Power up the focuser if necessary and check that the focuser control program is running and connected.

  • Power up mount if necessery:

    • switch on power supply on ePower #1 if not yet powered up. Normally it should be on.

    • then toggle mount switch both on ePower #1 if not yet powered up.

    • checked if Mount handpad control program connects properly.

  • Power up imager/s on ePower #1 if not yet powered up. Normally it should be off on starting up.

  • open dome


How to start up observatory (embedded images)

  • Check weather (outside conditions) use common sense

  • Log on to control PC via VNC skydome.mpe.mpg.de port 5200

  • 1st check if mount handpad program and focuser program are running and connected to mount and focuser respectively.

    xx xx

    • This should usally be the case.
    • If not start the programs and try to connect.
  • If they are not started, and cannot connect, then start up windows internet explorer.

    Internet explorer

  • Then Log on to ePower #1 and check if focuser and mount are powered on ePower #1. xx

  • Power up the focuser if necessary and check that the focuser control program is running and connected.

  • Power up mount if necessery:

    • switch on power supply on ePower #1 if not yet powered up. Normally it should be on.

    xx

    • then toggle mount switch both on ePower #1 if not yet powered up.

    xx

    • checked if Mount handpad control program connects properly.

  • Power up imager/s on ePower #1 if not yet powered up. Normally it should be off on starting up. xx

  • open dome


How to start up GOWI

  • cool imager to target temperature (-30C typically)
  • start dark and bias frame sequence
  • set focuser to expected setting for the night (if known)
  • take skyflats until start of actual observations