Differences between revisions 9 and 10
Revision 9 as of 2006-11-17 13:52:11
Size: 8316
Comment:
Revision 10 as of 2006-11-17 15:13:53
Size: 8429
Comment:
Deletions are marked like this. Additions are marked like this.
Line 20: Line 20:
 * '''PACS_Spec_OBS'''  * see PACS-ME-TP-007
Line 25: Line 25:
 * '''PACS_Spec_OBS'''  * see PACS-ME-TP-007
Line 30: Line 30:
 * '''PACS_Spec_OBS'''
 * see PACS-ME-TP-007
Line 185: Line 184:
   * procedure '''SPEC_init_det_setup'''
   * procedure '''SPEC_CRE_setup'''
   * procedure '''SPEC_heater_setup'''
   * procedure '''SPEC_fltw_conf'''
   * procedure '''SPEC_fltw_move'''
Line 187: Line 191:
   * block '''OBCP_spec_2_3_chop'''
Line 189: Line 192:
   * block '''OBCP_spec_2_3_chop'''
   * block '''OBCP_spec_2_3_chop'''
   * procedure '''SPEC_fltw_conf'''
   * procedure '''SPEC_fltw_move'''
   * block '''OBCP_spec_2_3_chop''' (3x)
Line 196: Line 196:
   * procedure '''SPEC_dpu_dmc_reset'''    * individual commands to switch-off SPECs and DECs in a time-delayed way
   * procedure '''OBCP_SAFE'''


PACS spectrometer operation from the commanding point of view


T. Mueller, D. Cesarsky; 10-Nov-2006

Index TableOfContents(2)


1. Short Functional Tests (Ge:Ga-detector related)


1.1. SFT Warm: Heater, flasher and Ge:Ga detector chain

  • see PACS-ME-TP-007

1.2. SFT at HeI: Heater, flasher and Ge:Ga detector chain

  • see PACS-ME-TP-007

1.3. SFT at HeII: Heater, flasher and Ge:Ga detector chain

  • see PACS-ME-TP-007


2. Nominal Operations


2.1. Instrument switch-on and connection of the warm electronic boxes

  • currently done with tcl-script PACS_Switch_On.tcl (maintained by FGB)

  • after execution: PACS is in SAFE mode

2.2. General Setup for Spectrometer Operation

  • starting out of SAFE mode

  • mode SPEC_setup_OBS calling the block SPEC_setup, calling the following CUS procedures:

    • procedure SPEC_dpu_dmc_setup (hk-list, rec_opt, fpga)
    • procedure SPEC_init_det_setup (initial detector setup, including switch-on of the SPECs and the correct selection of the CREs)
    • procedure SPEC_CRE_setup
    • procedure SPEC_dmc_setup
      • procedure SPEC_fltw_conf
      • procedure SPEC_fltw_move
      • procedure CONF_chopper
      • procedure CHOP_on_off
      • procedure CONF_cs
      • procedure CS_on_off
      • procedure CS_temp
      • procedure CONF_grating
    • procedure SPEC_spu_setup
    • AF5 enabled
  • ending up in Spectroscopy mode, but SPU processing has not yet started

  • default SPU mode: slope fitting for 64 readouts per ramp, no sub-ramps, default compression mode
  • filter is in position "A",
  • chopper enabled and at position "0"
  • grating is homed (with 1deg/sec, neg. direction) and enabled for nominal operations with a speed of 4deg/sec and positioned at 500000
  • calibration sources are set to default values (takes about 40-50 min stabilisation time)
  • blue detector heater is switched on and a current of 1.5 mA is applied (takes about 20 min stablisation time)
  • Autonomy function 5 "COUNTER_SPEC" is enabled

2.3. Operation of the spectrometers (starting out of '''Spectroscopy mode''')

2.3.1. start/stop of bolometer data flow

  • mode SPEC_spu_setup_OBS calling procedure SPEC_spu_setup ---> spectrometer data flow running

  • mode SPEC_spu_reset_OBS calling procedure SPEC_spu_reset ---> spectrometer data flow stopped

  • for modified SPU settings: SPEC_spu_setup_OBS.tcl <parameters>

2.3.2. Take data with manual chopper, grating & filter movements

  • mode SPEC_spu_setup_OBS calling procedure SPEC_spu_setup ---> spectrometer data flow running

    • mode PACS_fltw_move_OBS calling procedure SPEC_fltw_move (or PHOT_fltw_move)

    • or command Pacs_DMC_MOVE_CHOP_ABS

    • or command Pacs_DMC_MOVE_CHOP_REL

    • or command Pacs_DMC_MOVE_GRAT_ABS

    • or command Pacs_DMC_MOVE_GRAT_REL

  • mode SPEC_spu_reset_OBS calling procedure SPEC_spu_reset ---> spectrometer data flow stopped

Note: PACS_fltw_move_OBS can be called via a specific tcl-script where the filter has to be specified.

2.3.3. Take data with pre-defined OBCPs

  • mode OBCP_chop_scan_spec_OBS calling blocks/procedures:

    • procedure SPEC_spu_setup

    • procedure SPEC_fltw_move

    • block OBCP_chop_scan_spec

    • procedure SPEC_fltw_move

    • block OBCP_chop_scan_spec

    • procedure SPEC_fltw_move

    • procedure SPEC_spu_reset

  • mode OBCP_grat_scan_nochop_OBS calling blocks/procedures:

    • procedure SPEC_spu_setup

    • block OBCP_grat_scan_nochop

    • procedure SPEC_spu_reset

  • mode OBCP_spec_2_3_chop_OBS calling blocks/procedures:

    • procedure SPEC_spu_setup

    • block OBCP_spec_2_3_chop

    • procedure SPEC_spu_reset

  • mode OBCP_grat_line_scan_chop_2_OBS calling blocks/procedures:

    • procedure SPEC_spu_setup

    • block OBCP_grat_line_scan_chop_2

    • procedure SPEC_spu_reset

  • mode OBCP_gra_scan_chop2_fast_OBS calling blocks/procedures:

    • procedure SPEC_spu_setup

    • block OBCP_gra_scan_chop2_fast

    • procedure SPEC_spu_reset

  • mode OBCP_spec_freq_switch_OBS calling blocks/procedures:

    • procedure SPEC_spu_setup

    • block OBCP_spec_freq_switch

    • procedure SPEC_spu_reset

  • mode OBCP_chop_grat_scan_cal_OBS calling blocks/procedures:

    • procedure SPEC_spu_setup

    • block OBCP_chop_grat_scan_cal

    • procedure SPEC_spu_reset

  • mode SPEC_all_aots_OBS calling the following blocks/procedures:

    • procedure SPEC_spu_setup

    • procedure SPEC_fltw_move

    • block OBCP_spec_2_3_chop

    • block OBCP_spec_2_3_chop_dither

    • block OBCP_grat_line_scan_chop_2

    • block OBCP_grat_scan_chop2_fast

    • block OBCP_grat_scan_nochop

    • block OBCP_spec_2_3_chop

    • block OBCP_chop_grat_scan_cal

    • block OBCP_chop_scan_spec

    • block OBCP_spec_freq_switch

    • procedure SPEC_fltw_move

    • block OBCP_spec_2_3_chop

    • block OBCP_spec_2_3_chop_dither

    • block OBCP_grat_line_scan_chop_2

    • block OBCP_grat_scan_chop2_fast

    • block OBCP_grat_scan_nochop

    • block OBCP_spec_2_3_chop

    • block OBCP_chop_grat_scan_cal

    • block OBCP_chop_scan_spec

    • block OBCP_spec_freq_switch

    • procedure SPEC_fltw_move

    • procedure SPEC_spu_reset

Note: all these modes can be started with default parameters via the generic tcl-script; the key-OBCPs can also be started with freely selectable parameters via specific tcl-scripts

2.3.4. Execute AOT observations

  • CUS scripts (to be finalised):BR

2.4. Reset after spectrometer operation

  • PACS is in SPECTROSCOPY

  • execute mode SAFE mode

2.5. Instrument switch-off

  • currently done with the tcl-script PACS_Switch_Off.tcl (maintained by FGB)

  • after execution: PACS is switched off


3. Specific Spectrometer Tests


3.1. Thermal Behaviour Test

  • starting out of SAFE mode

  • mode SPEC_thermal_OBS calling the following blocks/procedures:

    • procedure SPEC_dpu_dmc_setup

    • procedure SPEC_init_det_setup

    • procedure SPEC_CRE_setup

    • procedure SPEC_heater_setup

    • procedure SPEC_fltw_conf

    • procedure SPEC_fltw_move

    • procedure CONF_chopper

    • procedure CHOP_on_off

    • procedure CONF_grating

    • block OBCP_spec_2_3_chop (3x)

    • procedure CONF_cs

    • procedure CS_on_off

    • procedure CS_temp

    • individual commands to switch-off SPECs and DECs in a time-delayed way
    • procedure OBCP_SAFE

  • ending up in SAFE mode

3.2. SPU Modes & Detector Selection Tests

3.3. Other Tests


4. NOTES


  • the SFT tests are described in PACS-ME-TP-007
  • some specific spectrometer tests, like the thermal behaviour measurement, start directly out of SAFE mode, while most of the tests will be executed after the SPEC_setup_OBS when the instrument is in Spectroscoy mode

  • the above mentioned CUS scripts (with a few exceptions) have been tested and are available in the CUS database and from the CVS library
  • the AOT related CUS-scripts are still under testing

Herschel: PACS/FM_ILT_Procedures/SpecOperations (last edited 2009-07-15 14:32:36 by localhost)