PACS bolometer operation from the commanding point of view


T. Mueller, D. Cesarsky; 08-Nov-2006


= SFT Warm: Sorption Cooler and Bolometer detector chain=


- PACS_Phot_SFT_Cooler_Warm_OBS, calling PACS_Phot_SFT_Cooler_WarmBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Warm_Startinputsignal_OBS, calling PACS_Phot_Warm_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR


= SFT at HeI: Sorption Cooler and Bolometer detector chain=


- PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR


= SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain=


- PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR


1. Instrument switch-on and connection of the warm electronic boxes


- currently done with tcl-script PACS_Switch_On.tcl (maintained by FGB)BR - after execution: PACS is in SAFE mode


2. Cooler recycling (only at HeII temperatures)


- starting out of SAFE modeBR - CUS script: BOLO_cool_recycle (no sub-procedures are called)BR - ending up in SAFE modeBR


3. General Setup for Photometer Operation (at warm, HeI, HeII temperatures and after cooler recycling)


- starting out of SAFE modeBR - CUS script:BR


4. Operation of the bolometers (starting out of PHOTOMETRY mode)


4.1. start/stop of bolometer data flow

4.2. Change of the bolometer data/sequence mode and gain

4.3. Take data with manual chopper & filter movements

4.4. Take data with pre-defined OBCPs

4.5. Execute AOT observations


5. Reset after photometer operation



6. Instrument switch-off



7. NOTES