Differences between revisions 8 and 9
Revision 8 as of 2006-11-08 13:39:56
Size: 10463
Comment:
Revision 9 as of 2006-11-08 14:36:31
Size: 11630
Comment:
Deletions are marked like this. Additions are marked like this.
Line 11: Line 11:
= SFT Warm: Sorption Cooler and Bolometer detector chain = = Short functional tests =
------------------------------------------------------------------------------------

------------------------------------------------------------------------------------
== SFT Warm: Sorption Cooler and Bolometer detector chain ==
Line 21: Line 25:
- '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''

------------------------------------------------------------------------------------
= SFT at HeI: Sorption Cooler and Bolometer detector chain =
------------------------------------------------------------------------------------
- '''PACS_Phot_SFT_Cooler_OBS''', calling '''PACS_Phot_SFT_Cooler'''[[BR]]

- '''PACS_Phot_DPU_DMC_Setup_OBS''', calling '''PACS_Phot_DPU_DMC_Setup'''[[BR]]
- '''PACS_Phot_Switchon_OBS''', calling '''PACS_Phot_Switchon'''[[BR]]
- '''PACS_Phot_Sequencer_Setup_OBS''', calling '''PACS_Phot_Sequencer_Setup'''[[BR]]
- '''PACS_Phot_SPU_Setup_OBS''', calling '''PACS_Phot_SPU_Setup'''[[BR]]
- '''PACS_Phot_Cold_Startinputsignal_OBS''', calling '''PACS_Phot_Cold_Startinputsignal''' (Duration: 637 sec)[[BR]]
- '''PACS_Phot_SPU_Reset_OBS''', calling '''PACS_Phot_SPU_Reset'''[[BR]]
- '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''

------------------------------------------------------------------------------------
= SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain =
- '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''[[BR]]

Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)

------------------------------------------------------------------------------------
== SFT at HeI: Sorption Cooler and Bolometer detector chain ==
Line 49: Line 42:

------------------------------------------------------------------------
= Instrument switch-on and connection of the warm electronic boxes =
Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)

------------------------------------------------------------------------------------
== SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain ==
------------------------------------------------------------------------------------
- '''PACS_Phot_SFT_Cooler_OBS''', calling '''PACS_Phot_SFT_Cooler'''[[BR]]

- '''PACS_Phot_DPU_DMC_Setup_OBS''', calling '''PACS_Phot_DPU_DMC_Setup'''[[BR]]
- '''PACS_Phot_Switchon_OBS''', calling '''PACS_Phot_Switchon'''[[BR]]
- '''PACS_Phot_Sequencer_Setup_OBS''', calling '''PACS_Phot_Sequencer_Setup'''[[BR]]
- '''PACS_Phot_SPU_Setup_OBS''', calling '''PACS_Phot_SPU_Setup'''[[BR]]
- '''PACS_Phot_Cold_Startinputsignal_OBS''', calling '''PACS_Phot_Cold_Startinputsignal''' (Duration: 637 sec)[[BR]]
- '''PACS_Phot_SPU_Reset_OBS''', calling '''PACS_Phot_SPU_Reset'''[[BR]]
- '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''[[BR]]

Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)

------------------------------------------------------------------------------------
= Nominal operations =
------------------------------------------------------------------------------------

------------------------------------------------------------------------
== Instrument switch-on and connection of the warm electronic boxes ==
Line 54: Line 67:
- after execution: PACS is in SAFE mode, the bolometer groups are off, but the temperature sensors are on


------------------------------------------------------------------------
= Cooler recycling (only at HeII temperatures) =
- after execution: PACS is in SAFE mode, the bolometer groups are off, but the temperature sensors are on[[BR]]

Note: Autonomy function #6 is enabled to check for the communication between DMC and BOLC


------------------------------------------------------------------------
=
= Cooler recycling (only at HeII temperatures) ==
Line 66: Line 81:
Note: Autonomy function 14 checks for TEMP_EV, TEMP_FPU1, TEMP_FPU2:[[BR]] Note: At the end of the recycling the autonomy function 14 is enabled. It checks for TEMP_EV, TEMP_FPU1, TEMP_FPU2:[[BR]]
Line 72: Line 87:
= General Setup for Photometer Operation (after cooler recycling) = == General Setup for Photometer Operation (after cooler recycling) ==
Line 95: Line 110:

------------------------------------------------------------------------
= Operation of the bolometers (starting out of PHOTOMETRY mode) =
------------------------------------------------------------------------

== start/stop of bolometer data flow ==
Note: At the end of the PHOT_setup the autonomy function 17 "generate_event_pwr" is enabled. It checks for the HK entries: PC_PWR_ANA_P_#, PC_PWR_ANA_N_# and PC_PWR_DIG_#, with # = [1,2,3,4,5,6,7]
 
------------------------------------------------------------------------
== Operation of the bolometers (starting out of PHOTOMETRY mode) ==
------------------------------------------------------------------------

=== start/stop of bolometer data flow ===
Line 108: Line 124:
== Change of the bolometer data/sequence mode and gain == === Change of the bolometer data/sequence mode and gain ===
Line 117: Line 133:
== Take data with manual chopper & filter movements ==
        CUS scripts:[[BR]]
               - procedure '''PHOT_spu_setup''' ---> bolometer data flow running[[BR]]
                   - procedure '''PHOT_fltw_move'''[[BR]]
=== Take data with manual chopper & filter movements ===
        CUS scripts:[[BR]]
               - '''PHOT_spu_setup_OBS''', '''PHOT_spu_setup''' ---> bolometer data flow running[[BR]]
                   - '''PHOT_fltw_move_OBS''', '''PHOT_fltw_move'''[[BR]]
Line 123: Line 139:
               - procedure '''PHOT_spu_reset'''[[BR]]


== Take data with pre-defined OBCPs ==
               - '''PHOT_spu_reset_OBS''', '''PHOT_spu_reset'''[[BR]] ---> bolometer data flow stopped


=== Take data with pre-defined OBCPs ===
Line 141: Line 157:
== Execute AOT observations == === Execute AOT observations ===
Line 172: Line 188:
= Reset after photometer operation = == Reset after photometer operation ==
Line 183: Line 199:
= Instrument switch-off = == Instrument switch-off ==
Line 192: Line 208:
  - there are more CUS scripts related to the SFT warm, HeI and HeII which are not mentioned here (see PACS-ME-TP-007)[[BR]]   - the SFT tests are described in PACS-ME-TP-007[[BR]]

TableOfContents(2)

PACS bolometer operation from the commanding point of view


T. Mueller, D. Cesarsky; 08-Nov-2006


1. Short functional tests



1.1. SFT Warm: Sorption Cooler and Bolometer detector chain


- PACS_Phot_SFT_Cooler_Warm_OBS, calling PACS_Phot_SFT_Cooler_WarmBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Warm_Startinputsignal_OBS, calling PACS_Phot_Warm_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR

Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)


1.2. SFT at HeI: Sorption Cooler and Bolometer detector chain


- PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR

Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)


1.3. SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain


- PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR

Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)


2. Nominal operations



2.1. Instrument switch-on and connection of the warm electronic boxes


- currently done with tcl-script PACS_Switch_On.tcl (maintained by FGB)BR - after execution: PACS is in SAFE mode, the bolometer groups are off, but the temperature sensors are onBR

Note: Autonomy function #6 is enabled to check for the communication between DMC and BOLC


2.2. Cooler recycling (only at HeII temperatures)


- starting out of SAFE mode (groups off, temperature sensors on) BR - CUS script:BR

  • mode BOLO_cooler_OBS calling the following CUS procedure:BR

    • - procedure BOLO_cool_recycle (no sub-procedures are called, the groups and temperature sensors are not touched, HK_list is set to PHOT_HK and reset to "NON-PRIME" in the end, autonomy function 14 is enabled), Duration: 7928 secBR

- ending up in SAFE mode (groups are off, temperature sensors on, HSP heater current at 1.18 mA)BR

Note: At the end of the recycling the autonomy function 14 is enabled. It checks for TEMP_EV, TEMP_FPU1, TEMP_FPU2:BR

  • --> HK DEC SOFT is generated if one or more are out of the range [260,320] mKBR --> GO SAFE is generated if one or more are above 400 mKBR


2.3. General Setup for Photometer Operation (after cooler recycling)


- starting out of SAFE mode (groups off, temperature sensors on)BR - CUS script:BR

  • block PHOT_setup calling the following CUS procedures:BR

    • - procedure PHOT_dpu_dmc_setupBR - procedure PHOT_dmc_setupBR

      • - procedure PHOT_fltw_conf BR - procedure CONF_chopper BR - procedure CONF_cs BR

      - procedure PHOT_switchon_groupsBR - procedure PHOT_set_bias (*)BR - procedure PHOT_seq_setupBR - procedure PHOT_change_data_modeBR - procedure PHOT_change_seq_modeBR - procedure PHOT_set_gainBR - procedure PHOT_spu_setupBR

  • (*) the bias tables to be loaded might change!BR

  • - ending up in PHOTOMETRY mode, but SPU processing has not yet startedBR - Note: filter is in position "A", chopper at position "0"BR - calibration sources are set to default values, but need 40-50 min stabilisation time!!!BR

Note: At the end of the PHOT_setup the autonomy function 17 "generate_event_pwr" is enabled. It checks for the HK entries: PC_PWR_ANA_P_#, PC_PWR_ANA_N_# and PC_PWR_DIG_#, with # = [1,2,3,4,5,6,7]


2.4. Operation of the bolometers (starting out of PHOTOMETRY mode)


2.4.1. start/stop of bolometer data flow

  • CUS scripts:BR

    • block PHOT_spu_setup_OBS calling the following CUS procedure:BR

      • - procedure PHOT_spu_setup ---> bolometer data flow running BR

      • block PHOT_spu_reset_OBS calling the following CUS procedure:BR

        • - procedure PHOT_spu_reset BR

2.4.2. Change of the bolometer data/sequence mode and gain

  • CUS scripts:BR

    • - procedure PHOT_change_data_modeBR - procedure PHOT_change_seq_modeBR - procedure PHOT_set_gainBR - or via MSTK with individual commands

2.4.3. Take data with manual chopper & filter movements

  • CUS scripts:BR

    • - PHOT_spu_setup_OBS, PHOT_spu_setup ---> bolometer data flow runningBR

      • - PHOT_fltw_move_OBS, PHOT_fltw_moveBR - command Pacs_DMC_MOVE_CHOP_ABSBR - command Pacs_DMC_MOVE_CHOP_RELBR

      - PHOT_spu_reset_OBS, PHOT_spu_resetBR ---> bolometer data flow stopped

2.4.4. Take data with pre-defined OBCPs

  • CUS scripts:BR

    • - procedure PHOT_spu_setup ---> bolometer data flow runningBR

      • - block OBCP_chopped_photometryBR - block OBCP_chopped_photometry_ditherBR - block OBCP_phot_freezeframeBR - block OBCP_phot_cal_IBR - block OBCP_phot_cal_IIBR - block OBCP_phot_cal_IIIBR - block OBCP_phot_staringBR - block OBCP_phot_chopper_scanBR

      • - block PHOT_all_aots_OBSBR

      - procedure PHOT_spu_resetBR

2.4.5. Execute AOT observations

  • CUS scripts (to be finalised):BR

    • PHOT_AOTBR

      • - PacsPhotDefaultsBR - PacsPhotEstimatorOBCPnBR

        • - PacsDureeOBCP5BR

          • - DMC_phot_2_3_chopBR

          - PacsDureeOBCP7BR

          • - DMC_staring_photBR

        Logic chooses and issues a pointing mode out of:BR

        • - composite_noddingBR - repeated_raster_with_holdBR - line_scan_with_holdBR

        - WriteOBSIDBR - PacsPhotSlewCalBR

        • - PHOT_aot_prologueBR

          • - PHOT_spu_setupBR

          - PHOT_fltw_moveBR - OBCP_chopped_photometryBR

        - PacsPhotCommandOBCP7BR

        • - OBCP_staring_photometryBR

        - PacsPhotCommandOBCP5BR

        • - OBCP_chopped_photometry_ditherBR

        - PHOT_aot_epilogueBR - WriteEndIDBR - PacsPhotNoiseRMSBR - PacsMessageCenterBR


2.5. Reset after photometer operation


  • - PACS is in PHOTOMETRY or any other modeBR - going into SAFE mode:BR

    • CUS scripts:BR

      • - block OBCP_SAFEBR

    - after execution: PACS is in SAFE modeBR


2.6. Instrument switch-off


  • - currently done with the tcl-script PACS_Switch_Off.tcl (maintained by FGB)BR - after execution: PACS is switched offBR


3. NOTES


  • - the SFT tests are described in PACS-ME-TP-007BR - some specific photometer tests, like the thermal behaviour measurements, start directly out of SAFE mode, while most of the tests will be executed after the PHOT_setup - the above mentioned CUS scripts (with a few exceptions) have been tested and are available in the CUS database and from the CVS libraryBR - the AOT related CUS-scripts are still under testing