Line 11: Line 11:
= SFT Warm: Sorption Cooler and Bolometer detector chain= = SFT Warm: Sorption Cooler and Bolometer detector chain =
Line 21: Line 21:
- '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''[[BR]] - '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''
Line 24: Line 24:
= SFT at HeI: Sorption Cooler and Bolometer detector chain= = SFT at HeI: Sorption Cooler and Bolometer detector chain =
Line 34: Line 34:
- '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''[[BR]] - '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''
Line 37: Line 37:
= SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain= = SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain =
Line 54: Line 54:
- after execution: PACS is in SAFE mode - after execution: PACS is in SAFE mode, the bolometer groups are off, but the
  temperature sensors are on
Line 60: Line 61:
- starting out of SAFE mode[[BR]]
- CUS script: '''BOLO_cool_recycle''' (no sub-procedures are called)[[BR]]
- ending up in SAFE mode[[BR]]
- starting out of SAFE mode (groups off, temperature sensors on) [[BR]] 
- CUS script: '''BOLO_cool_recycle''' (no sub-procedures are called,
  the groups and temperature sensors are not touched, HK_list is set
  to PHOT_HK and in the end reset to "NON-PRIME"
), Duration: 7928 sec[[BR]]
- ending up in SAFE mode (groups are off, temperature sensors on)[[BR]]
Line 68: Line 71:
- starting out of SAFE mode[[BR]] - starting out of SAFE mode (groups off, temperature sensors on)[[BR]]
Line 77: Line 80:
               - procedure PHOT_switchon_groups[[BR]]
Line 87: Line 91:
  - calibration sources are set to default values, but need 30-40 min stabilisation time!!![[BR]]   - calibration sources are set to default values, but need 40-50 min stabilisation time!!![[BR]]

TableOfContents(2)

PACS bolometer operation from the commanding point of view


T. Mueller, D. Cesarsky; 08-Nov-2006


1. SFT Warm: Sorption Cooler and Bolometer detector chain


- PACS_Phot_SFT_Cooler_Warm_OBS, calling PACS_Phot_SFT_Cooler_WarmBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Warm_Startinputsignal_OBS, calling PACS_Phot_Warm_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_Switchoff


2. SFT at HeI: Sorption Cooler and Bolometer detector chain


- PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_Switchoff


3. SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain


- PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR

- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR


4. Instrument switch-on and connection of the warm electronic boxes


- currently done with tcl-script PACS_Switch_On.tcl (maintained by FGB)BR - after execution: PACS is in SAFE mode, the bolometer groups are off, but the

  • temperature sensors are on


5. Cooler recycling (only at HeII temperatures)


- starting out of SAFE mode (groups off, temperature sensors on) BR - CUS script: BOLO_cool_recycle (no sub-procedures are called,

  • the groups and temperature sensors are not touched, HK_list is set

    to PHOT_HK and in the end reset to "NON-PRIME"), Duration: 7928 secBR

- ending up in SAFE mode (groups are off, temperature sensors on)BR


6. General Setup for Photometer Operation (at warm, HeI, HeII temperatures and after cooler recycling)


- starting out of SAFE mode (groups off, temperature sensors on)BR - CUS script:BR

  • block PHOT_setup calling the following CUS procedures (will be renamed to PHOT_orbit_prologue):

    • - procedure PHOT_dpu_dmc_setupBR - procedure PHOT_dmc_setupBR

      • - procedure PHOT_fltw_conf (*)BR - procedure CONF_chopper (*)BR - procedure CONF_cs (*)BR

      - procedure PHOT_switchon_groupsBR - procedure PHOT_set_bias (*)BR - procedure PHOT_seq_setupBR - procedure PHOT_change_data_modeBR - procedure PHOT_change_seq_modeBR - procedure PHOT_set_gainBR - procedure PHOT_spu_setupBR

  • (*) certain parameter values depend on the temperature environment!BR

  • - ending up in PHOTOMETRY mode, but SPU processing has not yet startedBR - Note: filter is in position "A", chopper at position "0"BR - calibration sources are set to default values, but need 40-50 min stabilisation time!!!BR


7. Operation of the bolometers (starting out of PHOTOMETRY mode)


7.1. start/stop of bolometer data flow

  • CUS scripts:BR

    • - procedure PHOT_spu_setup ---> bolometer data flow running BR - procedure PHOT_spu_reset BR

7.2. Change of the bolometer data/sequence mode and gain

  • CUS scripts:BR

    • - procedure PHOT_change_data_modeBR - procedure PHOT_change_seq_modeBR - procedure PHOT_set_gainBR

7.3. Take data with manual chopper & filter movements

  • CUS scripts:BR

    • - procedure PHOT_spu_setup ---> bolometer data flow runningBR

      • - procedure PHOT_fltw_moveBR - command Pacs_DMC_MOVE_CHOP_ABSBR - command Pacs_DMC_MOVE_CHOP_RELBR

      - procedure PHOT_spu_resetBR

7.4. Take data with pre-defined OBCPs

  • CUS scripts:BR

    • - procedure PHOT_spu_setup ---> bolometer data flow runningBR

      • - block OBCP_chopped_photometryBR - block OBCP_chopped_photometry_ditherBR - block OBCP_phot_freezeframeBR - block OBCP_phot_cal_IBR - block OBCP_phot_cal_IIBR - block OBCP_phot_cal_IIIBR - block OBCP_phot_staringBR - block OBCP_phot_chopper_scanBR

      • - block PHOT_all_aots_OBSBR

      - procedure PHOT_spu_resetBR

7.5. Execute AOT observations

  • CUS scripts (to be finalised):BR

    • PHOT_AOTBR

      • - PacsPhotDefaultsBR - PacsPhotEstimatorOBCPnBR

        • - PacsDureeOBCP5BR

          • - DMC_phot_2_3_chopBR

          - PacsDureeOBCP7BR

          • - DMC_staring_photBR

        Logic chooses and issues a pointing mode out of:BR

        • - composite_noddingBR - repeated_raster_with_holdBR - line_scan_with_holdBR

        - WriteOBSIDBR - PacsPhotSlewCalBR

        • - PHOT_aot_prologueBR

          • - PHOT_spu_setupBR

          - PHOT_fltw_moveBR - OBCP_chopped_photometryBR

        - PacsPhotCommandOBCP7BR

        • - OBCP_staring_photometryBR

        - PacsPhotCommandOBCP5BR

        • - OBCP_chopped_photometry_ditherBR

        - PHOT_aot_epilogueBR - WriteEndIDBR - PacsPhotNoiseRMSBR - PacsMessageCenterBR


8. Reset after photometer operation


  • - PACS is in PHOTOMETRY or any other modeBR - going into SAFE mode:BR

    • CUS scripts:BR

      • - block OBCP_SAFEBR

    - after execution: PACS is in SAFE modeBR


9. Instrument switch-off


  • - currently done with the tcl-script PACS_Switch_Off.tcl (maintained by FGB)BR - after execution: PACS is switched offBR


10. NOTES


  • - there are more CUS scripts related to the SFT warm, HeI and HeII which are not mentioned here (see PACS-ME-TP-007)BR - some specific photometer tests, like the thermal behaviour measurements, start directly out of SAFE mode, while most of the tests will be executed after the PHOT_setup - the above mentioned CUS scripts (with a few exceptions) have been tested and are available in the CUS database and from the CVS libraryBR - the AOT related CUS-scripts are still under testing