mode '''BOLO_cooler_OBS''' calling the CUS procedure '''BOLO_cool_recycle''': (no sub-procedures are called, the groups and temperature sensors are not touched, HK_list is set to PHOT_HK and reset to "NON-PRIME" in the end, autonomy function 14 is enabled, Duration: 7928 sec)[[BR]] |
mode '''BOLO_cooler_OBS''' calling the CUS procedure '''BOLO_cool_recycle''':[[BR]] - no sub-procedures are called, the groups and temperature sensors are not touched[[BR]] - HK_list is set to PHOT_HK and reset to "NON-PRIME" in the end[[BR]] - autonomy function 14 is enabled, Duration: 7928 sec[[BR]] |
Line 104: | Line 104: |
- procedure PHOT_set_gain[[BR]] | - procedure PHOT_set_gain(**)[[BR]] |
Line 107: | Line 107: |
(**) the gain setting can be 'high' or 'low' | |
Line 120: | Line 121: |
block '''PHOT_spu_setup_OBS''' calling the following CUS procedure:[[BR]] - procedure '''PHOT_spu_setup''' ---> bolometer data flow running [[BR]] block '''PHOT_spu_reset_OBS''' calling the following CUS procedure:[[BR]] - procedure '''PHOT_spu_reset''' [[BR]] |
block '''PHOT_spu_setup_OBS''' calling procedure '''PHOT_spu_setup''' ---> bolometer data flow running [[BR]] block '''PHOT_spu_reset_OBS''' calling procedure '''PHOT_spu_reset''' ---> bolometer data flow stopped [[BR]] |
Line 137: | Line 136: |
- '''PHOT_spu_setup_OBS''', '''PHOT_spu_setup''' ---> bolometer data flow running[[BR]] - '''PHOT_fltw_move_OBS''', '''PHOT_fltw_move'''[[BR]] |
block '''PHOT_spu_setup_OBS''' calling procedure '''PHOT_spu_setup''' ---> bolometer data flow running[[BR]] - block '''PHOT_fltw_move_OBS''' calling procedure '''PHOT_fltw_move'''[[BR]] |
Line 141: | Line 140: |
- '''PHOT_spu_reset_OBS''', '''PHOT_spu_reset'''[[BR]] ---> bolometer data flow stopped | block '''PHOT_spu_reset_OBS''' calling procedure '''PHOT_spu_reset''' ---> bolometer data flow stopped[[BR]] |
Line 146: | Line 145: |
- procedure '''PHOT_spu_setup''' ---> bolometer data flow running[[BR]] - block '''OBCP_chopped_photometry'''[[BR]] - block '''OBCP_chopped_photometry_dither'''[[BR]] - block '''OBCP_phot_freezeframe'''[[BR]] - block '''OBCP_phot_cal_I'''[[BR]] - block '''OBCP_phot_cal_II'''[[BR]] - block '''OBCP_phot_cal_III'''[[BR]] - block '''OBCP_phot_staring'''[[BR]] - block '''OBCP_phot_chopper_scan'''[[BR]] |
block '''PHOT_spu_setup_OBS''' calling procedure '''PHOT_spu_setup''' ---> bolometer data flow running [[BR]] - block '''OBCP_chopped_photometry_OBS'''[[BR]] - block '''OBCP_chopped_photometry_dither_OBS'''[[BR]] - block '''OBCP_phot_freezeframe_OBS'''[[BR]] - block '''OBCP_phot_cal_I_OBS'''[[BR]] - block '''OBCP_phot_cal_II_OBS'''[[BR]] - block '''OBCP_phot_cal_III_OBS'''[[BR]] - block '''OBCP_phot_staring_OBS'''[[BR]] - block '''OBCP_phot_chopper_scan_OBS'''[[BR]] block '''PHOT_spu_reset_OBS''' calling procedure '''PHOT_spu_reset''' ---> bolometer data flow stopped [[BR]] or block '''PHOT_spu_setup_OBS''' calling procedure '''PHOT_spu_setup''' ---> bolometer data flow running [[BR]] |
Line 156: | Line 160: |
- procedure '''PHOT_spu_reset'''[[BR]] |
block '''PHOT_spu_reset_OBS''' calling procedure '''PHOT_spu_reset''' ---> bolometer data flow stopped [[BR]] Note: all OBCPs can be started with default parameters via the generic tcl-script; the key-OBCPs can also be started with freely selectable parameters via specific tcl-scripts |
Line 193: | Line 199: |
- going into SAFE mode:[[BR]] CUS scripts:[[BR]] - block '''OBCP_SAFE'''[[BR]] |
- execute mode '''PHOT_switchoff_groups_OBS''' calling procedure '''PHOT_switchoff_groups'''[[BR]] (this will reset the biases sequentially, disable the AF 17, and switch off the groups)[[BR]] - going into SAFE mode[[BR]] (this will disable the AF 14 for the FPU temperature checks)[[BR]] |
Line 204: | Line 211: |
(this will disable the AF 6 for the DMC-BOLC communication check)[[BR]] |
PACS bolometer operation from the commanding point of view
T. Mueller, D. Cesarsky; 08-Nov-2006
1. Short functional tests
1.1. SFT Warm: Sorption Cooler and Bolometer detector chain
- PACS_Phot_SFT_Cooler_Warm_OBS, calling PACS_Phot_SFT_Cooler_WarmBR
- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Warm_Startinputsignal_OBS, calling PACS_Phot_Warm_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR
Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)
1.2. SFT at HeI: Sorption Cooler and Bolometer detector chain
- PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR
- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR
Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)
1.3. SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain
- PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR
- PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR - PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR - PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR - PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR - PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR - PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR - PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR
Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)
2. Nominal operations
2.1. Instrument switch-on and connection of the warm electronic boxes
- currently done with tcl-script PACS_Switch_On.tcl (maintained by FGB)BR - after execution: PACS is in SAFE mode, the bolometer groups are off, but the temperature sensors are onBR
Note: Autonomy function #6 is enabled to check for the communication between DMC and BOLC
2.2. Cooler recycling (only at HeII temperatures)
- starting out of SAFE mode (groups off, temperature sensors on) BR - CUS script:BR
mode BOLO_cooler_OBS calling the CUS procedure BOLO_cool_recycle:BR
- ending up in SAFE mode (groups are off, temperature sensors on, HSP heater current at 1.18 mA)BR
Note: At the end of the recycling the autonomy function 14 is enabled. It checks for TEMP_EV, TEMP_FPU1, TEMP_FPU2:BR
--> HK DEC SOFT is generated if one or more are out of the range [260,320] mKBR --> GO SAFE is generated if one or more are above 400 mKBR
2.3. General Setup for Photometer Operation (after cooler recycling)
- starting out of SAFE mode (groups off, temperature sensors on)BR - CUS script:BR
block PHOT_setup calling the following CUS procedures:BR
(*) the bias tables to be loaded might change!BR (**) the gain setting can be 'high' or 'low'
- ending up in PHOTOMETRY mode, but SPU processing has not yet startedBR - Note: filter is in position "A", chopper at position "0"BR - calibration sources are set to default values, but need 40-50 min stabilisation time!!!BR
Note: At the end of the PHOT_setup the autonomy function 17 "generate_event_pwr" is enabled. It checks for the HK entries: PC_PWR_ANA_P_#, PC_PWR_ANA_N_# and PC_PWR_DIG_#, with # = [1,2,3,4,5,6,7]
2.4. Operation of the bolometers (starting out of PHOTOMETRY mode)
2.4.1. start/stop of bolometer data flow
CUS scripts:BR
2.4.2. Change of the bolometer data/sequence mode and gain
CUS scripts:BR
2.4.3. Take data with manual chopper & filter movements
CUS scripts:BR
block PHOT_spu_setup_OBS calling procedure PHOT_spu_setup ---> bolometer data flow runningBR
- block PHOT_fltw_move_OBS calling procedure PHOT_fltw_moveBR - command Pacs_DMC_MOVE_CHOP_ABSBR - command Pacs_DMC_MOVE_CHOP_RELBR
block PHOT_spu_reset_OBS calling procedure PHOT_spu_reset ---> bolometer data flow stoppedBR
2.4.4. Take data with pre-defined OBCPs
CUS scripts:BR
block PHOT_spu_setup_OBS calling procedure PHOT_spu_setup ---> bolometer data flow running BR
- block OBCP_chopped_photometry_OBSBR - block OBCP_chopped_photometry_dither_OBSBR - block OBCP_phot_freezeframe_OBSBR - block OBCP_phot_cal_I_OBSBR - block OBCP_phot_cal_II_OBSBR - block OBCP_phot_cal_III_OBSBR - block OBCP_phot_staring_OBSBR - block OBCP_phot_chopper_scan_OBSBR
block PHOT_spu_reset_OBS calling procedure PHOT_spu_reset ---> bolometer data flow stopped BR or
block PHOT_spu_setup_OBS calling procedure PHOT_spu_setup ---> bolometer data flow running BR
- block PHOT_all_aots_OBSBR
block PHOT_spu_reset_OBS calling procedure PHOT_spu_reset ---> bolometer data flow stopped BR
- Note: all OBCPs can be started with default parameters via the generic tcl-script; the key-OBCPs can also be
- started with freely selectable parameters via specific tcl-scripts
2.4.5. Execute AOT observations
CUS scripts (to be finalised):BR
PHOT_AOTBR
- PacsPhotDefaultsBR - PacsPhotEstimatorOBCPnBR
Logic chooses and issues a pointing mode out of:BR
- WriteOBSIDBR - PacsPhotSlewCalBR
- PacsPhotCommandOBCP7BR
- OBCP_staring_photometryBR
- PacsPhotCommandOBCP5BR
- OBCP_chopped_photometry_ditherBR
- PHOT_aot_epilogueBR - WriteEndIDBR - PacsPhotNoiseRMSBR - PacsMessageCenterBR
2.5. Reset after photometer operation
- PACS is in PHOTOMETRY or any other modeBR - execute mode PHOT_switchoff_groups_OBS calling procedure PHOT_switchoff_groupsBR
(this will reset the biases sequentially, disable the AF 17, and switch off the groups)BR
- going into SAFE modeBR
(this will disable the AF 14 for the FPU temperature checks)BR
- after execution: PACS is in SAFE modeBR
2.6. Instrument switch-off
- currently done with the tcl-script PACS_Switch_Off.tcl (maintained by FGB)BR
(this will disable the AF 6 for the DMC-BOLC communication check)BR
- after execution: PACS is switched offBR
3. NOTES
- the SFT tests are described in PACS-ME-TP-007BR - some specific photometer tests, like the thermal behaviour measurements, start directly out of SAFE mode, while most of the tests will be executed after the PHOT_setup - the above mentioned CUS scripts (with a few exceptions) have been tested and are available in the CUS database and from the CVS libraryBR - the AOT related CUS-scripts are still under testing