= PACS bolometer operation from the commanding point of view = #pragma section-numbers on
'''Index'''
[[TableOfContents(2)]]

'''
PACS bolometer operation from the commanding point of view'''
Line 4: Line 8:
T. Mueller, D. Cesarsky
19-May-2006
T. Mueller, D. Cesarsky;
08-Nov-2006

------------------------------------------------------------------------------------
= Short functional tests =
------------------------------------------------------------------------------------


== SFT Warm: Sorption Cooler and Bolometer detector chain ==

 * '''PACS_Phot_SFT_Cooler_Warm_OBS''', calling '''PACS_Phot_SFT_Cooler_Warm'''[[BR]]

 * '''PACS_Phot_DPU_DMC_Setup_OBS''', calling '''PACS_Phot_DPU_DMC_Setup'''[[BR]]
 * '''PACS_Phot_Switchon_OBS''', calling '''PACS_Phot_Switchon'''[[BR]]
 * '''PACS_Phot_Sequencer_Setup_OBS''', calling '''PACS_Phot_Sequencer_Setup'''[[BR]]
 * '''PACS_Phot_SPU_Setup_OBS''', calling '''PACS_Phot_SPU_Setup'''[[BR]]
 * '''PACS_Phot_Warm_Startinputsignal_OBS''', calling '''PACS_Phot_Warm_Startinputsignal''' (Duration: 637 sec)[[BR]]
 * '''PACS_Phot_SPU_Reset_OBS''', calling '''PACS_Phot_SPU_Reset'''[[BR]]
 * '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''[[BR]]

__Note__: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)


== SFT at HeI: Sorption Cooler and Bolometer detector chain ==

 * '''PACS_Phot_SFT_Cooler_OBS''', calling '''PACS_Phot_SFT_Cooler'''[[BR]]

 * '''PACS_Phot_DPU_DMC_Setup_OBS''', calling '''PACS_Phot_DPU_DMC_Setup'''[[BR]]
 * '''PACS_Phot_Switchon_OBS''', calling '''PACS_Phot_Switchon'''[[BR]]
 * '''PACS_Phot_Sequencer_Setup_OBS''', calling '''PACS_Phot_Sequencer_Setup'''[[BR]]
 * '''PACS_Phot_SPU_Setup_OBS''', calling '''PACS_Phot_SPU_Setup'''[[BR]]
 * '''PACS_Phot_Cold_Startinputsignal_OBS''', calling '''PACS_Phot_Cold_Startinputsignal''' (Duration: 637 sec)[[BR]]
 * '''PACS_Phot_SPU_Reset_OBS''', calling '''PACS_Phot_SPU_Reset'''[[BR]]
 * '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''[[BR]]

__Note__: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)


== SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain ==

 * '''PACS_Phot_SFT_Cooler_OBS''', calling '''PACS_Phot_SFT_Cooler'''[[BR]]

 * '''PACS_Phot_DPU_DMC_Setup_OBS''', calling '''PACS_Phot_DPU_DMC_Setup'''[[BR]]
 * '''PACS_Phot_Switchon_OBS''', calling '''PACS_Phot_Switchon'''[[BR]]
 * '''PACS_Phot_Sequencer_Setup_OBS''', calling '''PACS_Phot_Sequencer_Setup'''[[BR]]
 * '''PACS_Phot_SPU_Setup_OBS''', calling '''PACS_Phot_SPU_Setup'''[[BR]]
 * '''PACS_Phot_Cold_Startinputsignal_OBS''', calling '''PACS_Phot_Cold_Startinputsignal''' (Duration: 637 sec)[[BR]]
 * '''PACS_Phot_SPU_Reset_OBS''', calling '''PACS_Phot_SPU_Reset'''[[BR]]
 * '''PACS_Phot_Switchoff_OBS''', calling '''PACS_Phot_Switchoff'''[[BR]]

__Note__: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)

------------------------------------------------------------------------------------
= Nominal operations =
------------------------------------------------------------------------------------


== Instrument switch-on and connection of the warm electronic boxes ==

 * currently done with tcl-script '''PACS_Switch_On.tcl''' (maintained by FGB)[[BR]]
 * after execution: PACS is in SAFE mode, the bolometer groups are off, but the temperature sensors are on[[BR]]

__Note__: Autonomy function #6 is enabled to check for the communication between DMC and BOLC



== Cooler recycling (only at HeII temperatures) ==

 * starting out of SAFE mode (groups off, temperature sensors on) [[BR]]
 * mode '''BOLO_cooler_OBS''' calling the CUS procedure '''BOLO_cool_recycle''':[[BR]]
             - no sub-procedures are called, the groups and temperature sensors are not touched[[BR]]
             - HK_list is set to PHOT_HK and reset to "NON-PRIME" in the end[[BR]]
             - autonomy function 14 is enabled, Duration: 7928 sec[[BR]]
 * ending up in SAFE mode (groups are off, temperature sensors on, HSP heater current at 1.18 mA)[[BR]]

__Note__: At the end of the recycling the autonomy function 14 is enabled. It checks for TEMP_EV, TEMP_FPU1, TEMP_FPU2: --> HK DEC SOFT is generated if one or more are out of the range [260,320] mK; --> GO SAFE is generated if one or more are above 400 mK
   


== General Setup for Photometer Operation (after cooler recycling) ==

 * starting out of SAFE mode (groups off, temperature sensors on)
 * mode '''PHOT_setup_OBS''' calling the block '''PHOT_setup''', calling the following CUS procedures:[[BR]]
               - procedure PHOT_dpu_dmc_setup[[BR]]
               - procedure PHOT_dmc_setup[[BR]]
                              - procedure PHOT_fltw_conf [[BR]]
                              - procedure CONF_chopper [[BR]]
                              - procedure CONF_cs [[BR]]
               - procedure PHOT_switchon_groups[[BR]]
               - procedure PHOT_set_bias (*)[[BR]]
               - procedure PHOT_seq_setup[[BR]]
               - procedure PHOT_change_data_mode[[BR]]
               - procedure PHOT_change_seq_mode[[BR]]
               - procedure PHOT_set_gain(**)[[BR]]
               - procedure PHOT_spu_setup[[BR]]
    (*) the bias tables to be loaded might change![[BR]]
    (**) the gain setting can be 'high' or 'low'

 * ending up in PHOTOMETRY mode, but SPU processing has not yet started
 * filter is in position "A", chopper at position "0"
 * calibration sources are set to default values, but need 40-50 min stabilisation time!!!

__Note__: At the end of the PHOT_setup the autonomy function 17 "generate_event_pwr" is enabled. It checks for the HK entries: PC_PWR_ANA_P_#, PC_PWR_ANA_N_# and PC_PWR_DIG_#, with # = [1,2,3,4,5,6,7]
 

== Operation of the bolometers (starting out of PHOTOMETRY mode) ==


=== start/stop of bolometer data flow ===
        mode '''PHOT_spu_setup_OBS''' calling procedure '''PHOT_spu_setup''' ---> bolometer data flow running [[BR]]
        mode '''PHOT_spu_reset_OBS''' calling procedure '''PHOT_spu_reset''' ---> bolometer data flow stopped [[BR]]


=== Change of the bolometer data/sequence mode and gain ===
        - procedure '''PHOT_change_data_mode'''[[BR]]
        - procedure '''PHOT_change_seq_mode'''[[BR]]
        - procedure '''PHOT_set_gain'''[[BR]]

        - or via MSTK with individual commands


=== Take data with manual chopper & filter movements ===
        mode '''PHOT_spu_setup_OBS''' calling procedure '''PHOT_spu_setup''' ---> bolometer data flow running[[BR]]
                   - block '''PHOT_fltw_move_OBS''' calling procedure '''PHOT_fltw_move'''[[BR]]
                   - command '''Pacs_DMC_MOVE_CHOP_ABS'''[[BR]]
                   - command '''Pacs_DMC_MOVE_CHOP_REL'''[[BR]]
        mode '''PHOT_spu_reset_OBS''' calling procedure '''PHOT_spu_reset''' ---> bolometer data flow stopped[[BR]]


=== Take data with pre-defined OBCPs ===
        mode '''PHOT_spu_setup_OBS''' calling procedure '''PHOT_spu_setup''' ---> bolometer data flow running [[BR]]
                       - block '''OBCP_chopped_photometry_OBS'''[[BR]]
                       - block '''OBCP_phot_chopper_scan_OBS'''[[BR]]
                       - block '''OBCP_fixed_fixed_photo_OBS'''[[BR]]
        mode '''PHOT_spu_reset_OBS''' calling procedure '''PHOT_spu_reset''' ---> bolometer data flow stopped [[BR]]

        or

        mode '''PHOT_spu_setup_OBS''' calling procedure '''PHOT_spu_setup''' ---> bolometer data flow running [[BR]]
                   - mode '''PHOT_all_aots_OBS''' calling the following procedures:[[BR]]
                            - procedure '''OBCP_chopped_photometry'''[[BR]]
                            - procedure '''OBCP_chopped_photometry_dither'''[[BR]]
                            - procedure '''OBCP_phot_freezeframe'''[[BR]]
                            - procedure '''OBCP_phot_cal_I'''[[BR]]
                            - procedure '''OBCP_phot_cal_II'''[[BR]]
                            - procedure '''OBCP_phot_cal_III'''[[BR]]
                            - procedure '''OBCP_phot_staring'''[[BR]]
                            - procedure '''OBCP_phot_chopper_scan'''[[BR]]
                            - procedure '''OBCP_fixed_fixed_photo'''[[BR]]
        mode '''PHOT_spu_reset_OBS''' calling procedure '''PHOT_spu_reset''' ---> bolometer data flow stopped [[BR]]

__Note__: all OBCPs can be started with default parameters via the generic tcl-script; the key-OBCPs can also be started with freely selectable parameters via specific tcl-scripts

=== Execute AOT observations ===
        CUS scripts (to be finalised):[[BR]]

            PHOT_AOT[[BR]]
               - PacsPhotDefaults[[BR]]
               - PacsPhotEstimatorOBCPn[[BR]]
                  - PacsDureeOBCP5[[BR]]
                     - DMC_phot_2_3_chop[[BR]]
                  - PacsDureeOBCP7[[BR]]
                     - DMC_staring_phot[[BR]]
               Logic chooses and issues a pointing mode out of:[[BR]]
                  - composite_nodding[[BR]]
                  - repeated_raster_with_hold[[BR]]
                  - line_scan_with_hold[[BR]]
               - WriteOBSID[[BR]]
               - PacsPhotSlewCal[[BR]]
                  - PHOT_aot_prologue[[BR]]
                     - PHOT_spu_setup[[BR]]
                  - PHOT_fltw_move[[BR]]
                  - OBCP_chopped_photometry[[BR]]
               - PacsPhotCommandOBCP7[[BR]]
                  - OBCP_staring_photometry[[BR]]
               - PacsPhotCommandOBCP5[[BR]]
                  - OBCP_chopped_photometry_dither[[BR]]
               - PHOT_aot_epilogue[[BR]]
               - WriteEndID[[BR]]
               - PacsPhotNoiseRMS[[BR]]
               - PacsMessageCenter[[BR]]

__Note__: the default OBCP for point-source photometry will probably be the OBCP_fixed_fixed_photo.


== Reset after photometer operation ==

 * PACS is in PHOTOMETRY or any other mode
 * execute mode '''PHOT_switchoff_groups_OBS''' calling procedure '''PHOT_switchoff_groups''' (this will reset the biases sequentially, disable the AF 17, and switch off the groups)
 * going into SAFE mode (this will disable the AF 14 for the FPU temperature checks)
 * after execution: PACS is in SAFE mode (groups are off, temperature sensors on, AF 6 enabled to check for the communication between DMC and BOLC)



== Instrument switch-off ==

 * currently done with the tcl-script '''PACS_Switch_Off.tcl''' (maintained by FGB) (this will disable the AF 6 for the DMC-BOLC communication check)
 * after execution: PACS is switched off
Line 9: Line 209:
 1. Instrument switch-on and connection of the warm electronic boxes = NOTES =
Line 11: Line 211:
  - currently done with tcl-script "PACS_Switch_On.tcl" (maintained by FGB):
  - after execution: PACS is in SAFE mode


------------------------------------------------------------------------
 2. Cooler recycling (only at HeII temperatures)
------------------------------------------------------------------------
  - starting out of SAFE mode
  - CUS script: BOLO_cool_recycle
                 (no sub-procedures are called)
  - ending up in SAFE mode


------------------------------------------------------------------------
 3. General Setup for Photometer Operation
     (at warm, HeI, HeII temperatures and after cooler recycling)
------------------------------------------------------------------------
  - starting out of SAFE mode
  - CUS script:
        block PHOT_setup calling the following CUS procedures
    (will be renamed to PHOT_orbit_prologue):
               - procedure PHOT_dpu_dmc_setup
               - procedure PHOT_dmc_setup
                              - procedure PHOT_fltw_conf (*)
                              - procedure CONF_chopper (*)
                              - procedure CONF_cs (*)
               - procedure PHOT_set_bias (*)
               - procedure PHOT_seq_setup
               - procedure PHOT_change_data_mode
               - procedure PHOT_change_seq_mode
               - procedure PHOT_set_gain
               - procedure PHOT_spu_setup
    (*) certain parameter values depend on the temperature
        environment!

  - ending up in PHOTOMETRY mode, but SPU processing has not yet
    started. Note: filter is in position "A", chopper at position "0",
    calibration sources are set to default values, but need 30-40 min
    stabilisation time!!!


------------------------------------------------------------------------
 4. Operation of the bolometers (starting out of PHOTOMETRY mode)
------------------------------------------------------------------------

     A) start/stop of bolometer data flow
        CUS scripts:
               - procedure PHOT_spu_setup
             ---> bolometer data flow running
               - procedure PHOT_spu_reset


     B) Change of the bolometer data/sequence mode and gain
        CUS scripts:
               - procedure PHOT_change_data_mode
               - procedure PHOT_change_seq_mode
               - procedure PHOT_set_gain


     C) Take data with manual chopper & filter movements
        CUS scripts:
               - procedure PHOT_spu_setup
             ---> bolometer data flow running
                   - procedure PHOT_fltw_move
                   - command Pacs_DMC_MOVE_CHOP_ABS
                   - command Pacs_DMC_MOVE_CHOP_REL
               - procedure PHOT_spu_reset


     D) Take data with pre-defined OBCPs
        CUS scripts:
               - procedure PHOT_spu_setup
             ---> bolometer data flow running
                       - block OBCP_chopped_photometry
                       - block OBCP_chopped_photometry_dither
                       - block OBCP_phot_freezeframe
                       - block OBCP_phot_cal_I
                       - block OBCP_phot_cal_II
                       - block OBCP_phot_cal_III
                       - block OBCP_phot_staring
                       - block OBCP_phot_chopper_scan
                        (not yet available!!!)
                   - block PHOT_all_aots_OBS
               - procedure PHOT_spu_reset


     E) Execute AOT observations
        CUS scripts (to be finalised):

            PHOT_AOT
               - PacsPhotDefaults
               - PacsPhotEstimatorOBCPn
                  - PacsDureeOBCP5
                     - DMC_phot_2_3_chop
                  - PacsDureeOBCP7
                     - DMC_staring_phot
               Logic chooses and issues a pointing mode out of:
                  - composite_nodding
                  - repeated_raster_with_hold
                  - line_scan_with_hold
               - WriteOBSID
               - PacsPhotSlewCal
                  - PHOT_aot_prologue
                     - PHOT_spu_setup
                  - PHOT_fltw_move
                  - OBCP_chopped_photometry
               - PacsPhotCommandOBCP7
                  - OBCP_staring_photometry
               - PacsPhotCommandOBCP5
                  - OBCP_chopped_photometry_dither
               - PHOT_aot_epilogue
               - WriteEndID
               - PacsPhotNoiseRMS
               - PacsMessageCenter


------------------------------------------------------------------------
 5. Reset after photometer operation
------------------------------------------------------------------------
  - PACS is in PHOTOMETRY or any other mode
  - going into SAFE mode:
        CUS scripts:
               - block OBCP_SAFE

  - after execution: PACS is in SAFE mode


------------------------------------------------------------------------
 6. Instrument switch-off
------------------------------------------------------------------------
  - currently done with a dedicated tcl-script (maintained by FGB)
  - after execution: PACS is switched off


------------------------------------------------------------------------
 7. NOTES
------------------------------------------------------------------------
  - there are more CUS scripts related to the SFT warm, HeI and HeII
    which are not mentioned here (see PACS-ME-TP-007)
  - some specific photometer tests, like the thermal behaviour
    measurements, start directly out of SAFE mode, while most
    of the tests will be executed after the "PHOT_setup"
  - the above mentioned CUS scripts (with a few exceptions) have been
    tested and are available in the CUS database and from the
    CVS library
  - the AOT related CUS-scripts are still under testing
 * the SFT tests are described in PACS-ME-TP-007
 * some specific photometer tests, like the thermal behaviour measurements, start directly out of SAFE mode, while most of the tests will be executed after the '''PHOT_setup'''
 * the above mentioned CUS scripts (with a few exceptions) have been tested and are available in the CUS database and from the CVS library
 * the AOT related CUS-scripts are still under testing

Index TableOfContents(2)

PACS bolometer operation from the commanding point of view


T. Mueller, D. Cesarsky; 08-Nov-2006


1. Short functional tests


1.1. SFT Warm: Sorption Cooler and Bolometer detector chain

  • PACS_Phot_SFT_Cooler_Warm_OBS, calling PACS_Phot_SFT_Cooler_WarmBR

  • PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR

  • PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR

  • PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR

  • PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR

  • PACS_Phot_Warm_Startinputsignal_OBS, calling PACS_Phot_Warm_Startinputsignal (Duration: 637 sec)BR

  • PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR

  • PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR

Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)

1.2. SFT at HeI: Sorption Cooler and Bolometer detector chain

  • PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR

  • PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR

  • PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR

  • PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR

  • PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR

  • PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR

  • PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR

  • PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR

Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)

1.3. SFT at HeII (cooler not recycled): Sorption Cooler and Bolometer detector chain

  • PACS_Phot_SFT_Cooler_OBS, calling PACS_Phot_SFT_CoolerBR

  • PACS_Phot_DPU_DMC_Setup_OBS, calling PACS_Phot_DPU_DMC_SetupBR

  • PACS_Phot_Switchon_OBS, calling PACS_Phot_SwitchonBR

  • PACS_Phot_Sequencer_Setup_OBS, calling PACS_Phot_Sequencer_SetupBR

  • PACS_Phot_SPU_Setup_OBS, calling PACS_Phot_SPU_SetupBR

  • PACS_Phot_Cold_Startinputsignal_OBS, calling PACS_Phot_Cold_Startinputsignal (Duration: 637 sec)BR

  • PACS_Phot_SPU_Reset_OBS, calling PACS_Phot_SPU_ResetBR

  • PACS_Phot_Switchoff_OBS, calling PACS_Phot_SwitchoffBR

Note: No specific autonomy functions are involved here (except AF#6 to check for the communication between DMC and BOLC)


2. Nominal operations


2.1. Instrument switch-on and connection of the warm electronic boxes

  • currently done with tcl-script PACS_Switch_On.tcl (maintained by FGB)BR

  • after execution: PACS is in SAFE mode, the bolometer groups are off, but the temperature sensors are onBR

Note: Autonomy function #6 is enabled to check for the communication between DMC and BOLC

2.2. Cooler recycling (only at HeII temperatures)

  • starting out of SAFE mode (groups off, temperature sensors on) BR

  • mode BOLO_cooler_OBS calling the CUS procedure BOLO_cool_recycle:BR

    • - no sub-procedures are called, the groups and temperature sensors are not touchedBR - HK_list is set to PHOT_HK and reset to "NON-PRIME" in the endBR - autonomy function 14 is enabled, Duration: 7928 secBR

  • ending up in SAFE mode (groups are off, temperature sensors on, HSP heater current at 1.18 mA)BR

Note: At the end of the recycling the autonomy function 14 is enabled. It checks for TEMP_EV, TEMP_FPU1, TEMP_FPU2: --> HK DEC SOFT is generated if one or more are out of the range [260,320] mK; --> GO SAFE is generated if one or more are above 400 mK

2.3. General Setup for Photometer Operation (after cooler recycling)

  • starting out of SAFE mode (groups off, temperature sensors on)
  • mode PHOT_setup_OBS calling the block PHOT_setup, calling the following CUS procedures:BR

    • - procedure PHOT_dpu_dmc_setupBR - procedure PHOT_dmc_setupBR

      • - procedure PHOT_fltw_conf BR - procedure CONF_chopper BR - procedure CONF_cs BR

      - procedure PHOT_switchon_groupsBR - procedure PHOT_set_bias (*)BR - procedure PHOT_seq_setupBR - procedure PHOT_change_data_modeBR - procedure PHOT_change_seq_modeBR - procedure PHOT_set_gain(**)BR - procedure PHOT_spu_setupBR

    • (*) the bias tables to be loaded might change!BR (**) the gain setting can be 'high' or 'low'

  • ending up in PHOTOMETRY mode, but SPU processing has not yet started
  • filter is in position "A", chopper at position "0"
  • calibration sources are set to default values, but need 40-50 min stabilisation time!!!

Note: At the end of the PHOT_setup the autonomy function 17 "generate_event_pwr" is enabled. It checks for the HK entries: PC_PWR_ANA_P_#, PC_PWR_ANA_N_# and PC_PWR_DIG_#, with # = [1,2,3,4,5,6,7]

2.4. Operation of the bolometers (starting out of PHOTOMETRY mode)

2.4.1. start/stop of bolometer data flow

  • mode PHOT_spu_setup_OBS calling procedure PHOT_spu_setup ---> bolometer data flow running BR mode PHOT_spu_reset_OBS calling procedure PHOT_spu_reset ---> bolometer data flow stopped BR

2.4.2. Change of the bolometer data/sequence mode and gain

  • - procedure PHOT_change_data_modeBR - procedure PHOT_change_seq_modeBR - procedure PHOT_set_gainBR - or via MSTK with individual commands

2.4.3. Take data with manual chopper & filter movements

  • mode PHOT_spu_setup_OBS calling procedure PHOT_spu_setup ---> bolometer data flow runningBR

    • - block PHOT_fltw_move_OBS calling procedure PHOT_fltw_moveBR - command Pacs_DMC_MOVE_CHOP_ABSBR - command Pacs_DMC_MOVE_CHOP_RELBR

    mode PHOT_spu_reset_OBS calling procedure PHOT_spu_reset ---> bolometer data flow stoppedBR

2.4.4. Take data with pre-defined OBCPs

  • mode PHOT_spu_setup_OBS calling procedure PHOT_spu_setup ---> bolometer data flow running BR

    • - block OBCP_chopped_photometry_OBSBR - block OBCP_phot_chopper_scan_OBSBR - block OBCP_fixed_fixed_photo_OBSBR

    mode PHOT_spu_reset_OBS calling procedure PHOT_spu_reset ---> bolometer data flow stopped BR or

    mode PHOT_spu_setup_OBS calling procedure PHOT_spu_setup ---> bolometer data flow running BR

    • - mode PHOT_all_aots_OBS calling the following procedures:BR

      • - procedure OBCP_chopped_photometryBR - procedure OBCP_chopped_photometry_ditherBR - procedure OBCP_phot_freezeframeBR - procedure OBCP_phot_cal_IBR - procedure OBCP_phot_cal_IIBR - procedure OBCP_phot_cal_IIIBR - procedure OBCP_phot_staringBR - procedure OBCP_phot_chopper_scanBR - procedure OBCP_fixed_fixed_photoBR

    mode PHOT_spu_reset_OBS calling procedure PHOT_spu_reset ---> bolometer data flow stopped BR

Note: all OBCPs can be started with default parameters via the generic tcl-script; the key-OBCPs can also be started with freely selectable parameters via specific tcl-scripts

2.4.5. Execute AOT observations

  • CUS scripts (to be finalised):BR

    • PHOT_AOTBR

      • - PacsPhotDefaultsBR - PacsPhotEstimatorOBCPnBR

        • - PacsDureeOBCP5BR

          • - DMC_phot_2_3_chopBR

          - PacsDureeOBCP7BR

          • - DMC_staring_photBR

        Logic chooses and issues a pointing mode out of:BR

        • - composite_noddingBR - repeated_raster_with_holdBR - line_scan_with_holdBR

        - WriteOBSIDBR - PacsPhotSlewCalBR

        • - PHOT_aot_prologueBR

          • - PHOT_spu_setupBR

          - PHOT_fltw_moveBR - OBCP_chopped_photometryBR

        - PacsPhotCommandOBCP7BR

        • - OBCP_staring_photometryBR

        - PacsPhotCommandOBCP5BR

        • - OBCP_chopped_photometry_ditherBR

        - PHOT_aot_epilogueBR - WriteEndIDBR - PacsPhotNoiseRMSBR - PacsMessageCenterBR

Note: the default OBCP for point-source photometry will probably be the OBCP_fixed_fixed_photo.

2.5. Reset after photometer operation

  • PACS is in PHOTOMETRY or any other mode
  • execute mode PHOT_switchoff_groups_OBS calling procedure PHOT_switchoff_groups (this will reset the biases sequentially, disable the AF 17, and switch off the groups)

  • going into SAFE mode (this will disable the AF 14 for the FPU temperature checks)
  • after execution: PACS is in SAFE mode (groups are off, temperature sensors on, AF 6 enabled to check for the communication between DMC and BOLC)

2.6. Instrument switch-off

  • currently done with the tcl-script PACS_Switch_Off.tcl (maintained by FGB) (this will disable the AF 6 for the DMC-BOLC communication check)

  • after execution: PACS is switched off


3. NOTES


  • the SFT tests are described in PACS-ME-TP-007
  • some specific photometer tests, like the thermal behaviour measurements, start directly out of SAFE mode, while most of the tests will be executed after the PHOT_setup

  • the above mentioned CUS scripts (with a few exceptions) have been tested and are available in the CUS database and from the CVS library
  • the AOT related CUS-scripts are still under testing