Differences between revisions 5 and 6
Revision 5 as of 2007-03-08 07:14:58
Size: 3356
Comment:
Revision 6 as of 2007-03-19 08:18:23
Size: 3846
Comment:
Deletions are marked like this. Additions are marked like this.
Line 116: Line 116:

{{{
Number : 7
Author : Ekki
Date/Time : 19-03-2007 / 08:00

Problem :
Only 2032 Packets (TestEquipment) indicated on DataRateMonitor. No instrument Packets (1052/1054) seen
by any system. CDMS Simulator producing Packets.

Immediate action :
Within 30 Seconds :
- Stop EventMonitor
- Restart Router
- Restart CDMS Simulator
- restart TEI Gateway, SCOS GAteway...

Later
- restart PowerSupply, Cryo Control and Test Optics
 
Further action :
No
}}}

Log for Data Processing Events

Example :

Number     : 1 
Author     : Ekki 
Date/Time  : 05-03-2007 / 11:22

Problem    :
We had no place to log problems in the Data Processing/ Dat Flow/ Software System setup

Immediate action :
Make a WIKI page for it
 
Further action   :
All Support personal to add entries

Number     : 2 
Author     : Ekki 
Date/Time  : 05-03-2007 / 12:32

Problem    :
DataRateMonitor was running but gave permanent error messages : Router connection

Immediate action :
Restart of DataRateMonitor
 
Further action   :
Not needed.

Number     : 3 
Author     : Wim
Date/Time  : 06-03-2007 / 08:20

Problem    :
QLA did not respond anymore. The following message did appear :

05-Mar-07 19:26:32.326 RouterProductStream: Router connection closed: Read fails
java.io.IOException: Failed to deregister apid 65: herschel.egserouter.RouterException: write failed
        at herschel.access.net.RouterConnection.deregister(RouterConnection.java:132)
        at herschel.access.net.RouterConnection.close(RouterConnection.java:181)
        at herschel.access.util.DataSelector$OpenHandler.run(DataSelector.java:394)
        at java.lang.Thread.run(Thread.java:595)
05-Mar-07 19:26:32.343 DataSelector$OpenHandler: Error closing stream: java.io.IOException: Failed to deregister apid 65: herschel.egserouter.RouterException: write failed
05-Mar-07 20:29:55.473 DataSelector$OpenHandler: Accessing with params NAME=herschel.versant.ccm.TmSourcePacketImpl
05-Mar-07 20:29:55.500 RouterConnection: Connecting to router on pacs-sv port 9877
05-Mar-07 20:29:55.506 RouterLink: HCSS Access Router Connector@Mon Mar 05 20:29:55 CET 2007 connected to pacs-sv:9877
05-Mar-07 21:57:13.946 RouterProductStream: Router connection closed: Read fails
java.io.IOException: Failed to deregister apid 68: herschel.egserouter.RouterException: write failed
        at herschel.access.net.RouterConnection.deregister(RouterConnection.java:132)
        at herschel.access.net.RouterConnection.close(RouterConnection.java:181)
        at herschel.access.util.DataSelector$OpenHandler.run(DataSelector.java:394)
        at java.lang.Thread.run(Thread.java:595)
05-Mar-07 21:57:13.969 DataSelector$OpenHandler: Error closing stream: java.io.IOException: Failed to deregister apid 68: herschel.egserouter.RouterException: write failed


Immediate action :
Restart of QLA
 
Further action   :
Not needed

Number     : 4 
Author     : Ekki 
Date/Time  : 07-03-2007 / 08:00

Problem    :
TmIngestion did run, but TmPacets were ingested any more
Remember we are running the Patch even !

Immediate action :
Check logs (just 0 ingestions indicated). Restart of TmIngestion
 
Further action   :
Urgent ! But what ?

Number     : 5 
Author     : Ekki 
Date/Time  : 07-03-2007 / 19:00

Problem    :
CDS Simulator shut down.

Immediate action :
Restart of all subsystems (Router, Gateways, PacketRecrder, TmIngestion etc.)
Restart CDMS Simulator
 
Further action   :
No

Number     : 6 
Author     : Ekki 
Date/Time  : 08-03-2007 / 08:00

Problem    :
Hourly Packet Recorder File was stopped around three in the morning
Daily and recored were running

Immediate action :
Restarted
 
Further action   :
No

Number     : 7 
Author     : Ekki 
Date/Time  : 19-03-2007 / 08:00

Problem    :
Only 2032 Packets (TestEquipment) indicated on DataRateMonitor. No instrument Packets (1052/1054) seen
by any system. CDMS Simulator producing Packets. 

Immediate action :
Within 30 Seconds :
- Stop EventMonitor
- Restart Router
- Restart CDMS Simulator
- restart TEI Gateway, SCOS GAteway...

Later
- restart PowerSupply, Cryo Control and Test Optics
 
Further action   :
No

Herschel: PACS/FM_ILT_Procedures/DataProcessingLog (last edited 2009-07-15 14:32:38 by localhost)