Line 5: Line 5:
= A new MIB (combination) is available and ready to be used = = Standard Procedures =
Line 7: Line 7:
A single procedure named "loadMIB" is used to ingest the MIB == A new MIB (combination) is available and ready to be used ==

A single procedure named "ccm" is used to ingest the MIB
Line 13: Line 15:
loadMIB --loadmib PACS_MIB_TAG EGSE_MIB_TAG CDMSSIM_MIB_TAG ccm -loadmib PACS_MIB_TAG EGSE_MIB_TAG CDMSSIM_MIB_TAG
Line 17: Line 19:
loadMib --loadmib=MIB_LABEL ccm -loadmib=MIB_LABEL
Line 23: Line 25:
= A new (modifiable) instrumentModel shall be created using new MIB definition = == A new (modifiable) instrumentModel shall be created using new MIB definition ==
Line 26: Line 28:
createInstrumentModel --create MIB_LABEL ccm -createmodel -usemib=MIB_LABEL -usecus=cvs=CVS_TAG comment

Describe PACS/FM ILT Procedures/CCMprocedures here.

TableOfContents(2)

Standard Procedures

A new MIB (combination) is available and ready to be used

A single procedure named "ccm" is used to ingest the MIB into both the operations and the CUS development databases.

The MIB to be ingested can be specified in two different ways, either by the CVS MibTags or by the database MibLabels.

ccm -loadmib PACS_MIB_TAG EGSE_MIB_TAG CDMSSIM_MIB_TAG

or

ccm -loadmib=MIB_LABEL

The MIB loading does not affect any ongoing operation. It can be executed at any time.

A new (modifiable) instrumentModel shall be created using new MIB definition

ccm -createmodel -usemib=MIB_LABEL -usecus=cvs=CVS_TAG comment

This command will create a new modifiable instrumentModel in the operations database. The corresponding MIB will automatically associated with this new instrumentModel.

The [:InstrumentModelLabel: instrumentModel label] in the database will be formed according the given [:MibLabels: MibLabel]. If there is already an instrumentModel with this label the command will fail. To create a new version use the --force option.

createInstrumentModel --create MIB_LABEL --force

To load the initial CUS definitions (procedures and table) two options exist. Either copy the CUS definitions from an existing instrumentModel or use a tagged version from the CVS repository.

createInstrumentModel --loadcus=cvs=tagname instrumentModelLabel

or

createInstrumentModel --loadcus=instmodel=label instrumentModelLabel