Differences between revisions 8 and 9
Revision 8 as of 2008-02-12 14:54:47
Size: 1336
Editor: dcesarsky
Comment:
Revision 9 as of 2008-02-12 14:56:55
Size: 1453
Editor: dcesarsky
Comment:
Deletions are marked like this. Additions are marked like this.
Line 45: Line 45:

[wiki:Self:PACS/CUSPVscripts/SpecSpuSetup SPEC_spu_setup]

[wiki:Self:PACS/CUSPVscripts/WriteOBSID WriteOBSID]

PacsEngGeGa_SFT_Init_Warm

Expert HSPOT rendering of the IST mode PACS_GeGa_SFT_Init_Warm. There are no input parameters to invoke this OBS script. The module PACS_GeGa_SFT_Init_Warm is described as:

// Missionphase  : PACS EQM Test
//
// Purpose       : Warm SFT of Ge:Ga detector chain
//
// Author        : H. Feuchtgruber
//
// Arguments     : none
//
//
// Description   : This script will switch on and set all required parameters
//                 for a test of the Ge:Ga detector chain at RT temperature.
//                 Dummy resistor bias = 10 mV, detector bias = 2 mV
//
//
// Comments      :
//
// Version       : 1.0
// History       : 1.0 / 16-Nov-2004 initial version
// 1.1  7-mar-2006 TeleCommand Pacs_DMC_SET_B_SPEC_HEAT_1_C renamed
//                 TeleCommand Pacs_DMC_SET_B_SPEC_HEAT_2_C renamed
// 1.2 24-mar-2006 Large overhaul based on
//                 SetupSpectroscopyWEplusFPUsim.tcl script
// 1.3 27-nov-2006 Changed bias_d to LB value: 1mV
// 2.0  8-feb-2007 Added switchoff  SPECs and DECs
//

Calling syntax:

procedure PACS_GeGa_SFT_Init_Warm {
}{

The modules called when running this script are (in alphabetical order):

PACS_GeGa_SFT_Init_Warm

WriteEndID

WriteOBSID

[wiki:PACS/CUSPVscripts/SpecSpuSetup SPEC_spu_setup]

[wiki:PACS/CUSPVscripts/WriteOBSID WriteOBSID]

Herschel: PACS/CUSPVscripts/PacsEngGeGa_SFT_Init_Warm (last edited 2009-07-15 14:32:36 by localhost)