Differences between revisions 16 and 17
Revision 16 as of 2007-03-08 14:58:13
Size: 2808
Comment:
Revision 17 as of 2007-03-08 15:01:10
Size: 2825
Comment:
Deletions are marked like this. Additions are marked like this.
Line 38: Line 38:
# FPU angle : offset 650
print (664??? +) fpuAngle2ChopPosPol(Double1d([-4, 0, 4]))
# Sky angle : scaling factor 80.69
print ((664??? +)fpuAngle2ChopPosPol(Double1d([-4, 0, 4])))/80.69
# FPU angle in degrees:
print (664??? +) chopPos2FpuAnglePol(Double1d([-4, 0, 4]))
# Sky angle in arcmin : scaling factor 80.69
print ((664??? +)chopPos2FpuAnglePol(Double1d([-4, 0, 4])))*60./80.69
Line 44: Line 44:
664???: optical zero, not known yet, must first be defined and measured!
664 is the best guess for the optical zero using Zeiss measurements.
you get angles referred to the mechanical zero by using fpuAngle2ChopPosPol or chopPos2FpuAnglePol
#664???: optical zero, not known yet, must first be defined and measured!
#664 is the best guess for the optical zero using Zeiss measurements.
#you get angles referred to the mechanical zero by using fpuAngle2ChopPosPol or #chopPos2FpuAnglePol

FM ILT reference numbers

Ge:Ga detector settings

  • Blue
    • par

      value

      comment

      Bias d

      198 mV

      From bias / heater loop test

      Bias r

      10 mV

      Component level value - to be verified on CRE checkout test

      Heater

      1.5 mA

      Result from bias / heater loop test (2.68K/1.84mA) exceeds thermal budget

  • Red
    • par

      value

      comment

      Bias d

      69 mV

      From bias / heater loop test

      Bias r

      10 mV

      Component level value - to be verified on CRE checkout test

Grating

  • Configuration table: CONFGrat. Column : FMILTFast / FMILT_R_Fast for redundant
  • Allowed working range :
    • 45K - 1045K (nominal)
    • 65K - 1065K (redundant)
  • Conversion wavelength - grating position:

Chopper

  • !!! Do NOT use the chopper in redundant mode !!!
  • Configuration table CONFChopper / column : CSLopt3-600
  • Accessible range : -23000 to +23000
    • At +/- 25000 a field plate limit disables the controller
  • Conversion chopper position - angle on the sky - FPU angle :
    • FPU Angle

      Sky Angle

      Chopper pos

      Comment

      - 8.5 deg

      -6.32 arcmin

      -23382

      center CS1

      -4 deg

      -2.97 arcmin

      -12101

      0 deg

      0 arcmin

      0

      Mechanical zero

      +4 deg

      2.97 arcmin

      12431

      + 8.5 deg

      6.32 arcmin

      22347

      center CS2

  • Other angles - in the PCSS (release >20070303A) :

    • from all import *
      # FPU angle in degrees:
      print (664??? +) chopPos2FpuAnglePol(Double1d([-4, 0, 4]))
      # Sky angle in arcmin : scaling factor 80.69
      print ((664??? +)chopPos2FpuAnglePol(Double1d([-4, 0, 4])))*60./80.69
      
      
      #664???: optical zero, not known yet, must first be defined and measured!
      #664 is the best guess for the optical zero using Zeiss measurements.
      #you get angles referred to the mechanical zero by using fpuAngle2ChopPosPol or #chopPos2FpuAnglePol

Filter Wheel PHOT

  • POS A = Long wavelength (Green)
  • POS B = Short wavelength (Blue)

Filter Wheel SPEC

  • POS A = Short wavelength (50-70um)
  • POS B = Long wavelength (70-100um)

Calibration sources

  • CS1
    • 48 Ohm = 55K
    • Chopper position center : - TBD
  • CS2
    • 58 Ohm = 60K
    • Chopper position center : + TBD

XY stage

  • Scale: 1" on the sky = 0.18mm
  • Spectrometer
    • Focus : +5mm (from FMILT-1, not incompatible with spectro FMILT-2)
    • Center spectro field :
      • x = -12.8 mm
      • y = +1.2 mm
  • Photometer
    • Focus : +5mm (from FMILT-1)
    • Center field :
      • x = 4 mm
      • y = 0

Herschel: FmIltProc/ReferenceNumbers (last edited 2009-07-15 14:32:37 by localhost)