1. Filter Wheel control loop procedures

2. Conditions

All tests described can be executed from SAFE MODE of from SPECTROSCOPY.

3. Threshold Tuning

3.1. Threshold parameter optimisation Photometer filter wheel

A loop over steps 3 & 4 can be implemented for a number of thresholds

Script

TCL

Parameters

Comments

1

PACS_Phot_HK_Setup_OBS

2

PACS_Phot_Fil_Diaghk_Setup_OBS

3

CONF_phot_fltw_param_OBS

Yes

rate,drive_current,threshold

4

PACS_Phot_Fil_nturns_OBS

Yes

nturns : number of full turns of the FW

5

PACS_Diaghk_Reset_OBS

6

PACS_SAFE_MODE.tcl

3.2. Threshold parameter optimisation Spectrometer filter wheel

A loop over steps 3 & 4 can be implemented for a number of thresholds

Script

TCL

Parameters

Comments

1

PACS_Spec_HK_Setup_OBS

2

PACS_Spec_Fil_Diaghk_Setup_OBS

3

CONF_spec_fltw_param_OBS

Yes

rate,drive_current,threshold

4

PACS_Spec_Fil_nturns_OBS

Yes

nturns : number of full turns of the FW

5

PACS_Diaghk_Reset_OBS

6

PACS_SAFE_MODE.tcl

4. Current loop

4.1. Photometer filter wheel

Loop over current from 10 to 100mA by step of 10. For each setting, performs nturns *OPEN LOOP* movements of 360 degrees (default = 3). Open loop movement means that the wheel is driven for a given time, depending on the size of the movement and the rate. Consequently, the movement might finally not be of the expected size.

Script

TCL

Parameters

Comments

1

PACS_Phot_HK_Setup_OBS

2

PACS_Phot_Fil_Diaghk_Setup_OBS

3

CONF_phot_fltw_param_OBS

Yes

rate,drive_current,threshold

4

PACS_Phot_Fil_Current_Loop_OBS

No

nturns : #turns of the FW/current setting

5

PACS_Diaghk_Reset_OBS

6

PACS_SAFE_MODE.tcl